Create a new My List.
PRLV
More information about Senninger® Pressure Regulators
Product Information
Operating Specifications
Additional Information
| PRLV Models | |
|---|---|
| Part Number | Description |
| 3/4" x 3/4" NPT models | |
| PRLV10MF3F3FV | 10 psi, inlet 3/4" F NPT, outlet 3/4" F NPT w/ vane |
| PRLV15MF3F3FV | 15 psi, inlet 3/4" F NPT, outlet 3/4" F NPT w/ vane |
| PRLV20MF3F3FV | 20 psi, inlet 3/4" F NPT, outlet 3/4" F NPT w/ vane |
| PRLV30MF3F3FV | 30 psi, inlet 3/4" F NPT, outlet 3/4" F NPT w/ vane |
| PRLV40MF3F3FV | 40 psi, inlet 3/4" F NPT, outlet 3/4" F NPT w/ vane |
| PRLV50MF3F3FV | 50 psi, inlet 3/4" F NPT, outlet 3/4" F NPT w/ vane |
| PRLV60MF3F3FV | 60 psi, inlet 3/4" F NPT, outlet 3/4" F NPT w/ vane |
| 1" x 1" NPT models | |
| PRLV10MF4F4FV | 10 psi, inlet 1" F NPT, outlet 1" F NPT w/ vane |
| PRLV15MF4F4FV | 15 psi, inlet 1" F NPT, outlet 1" F NPT w/ vane |
| PRLV20MF4F4FV | 20 psi, inlet 1" F NPT, outlet 1" F NPT w/ vane |
| PRLV30MF4F4FV | 30 psi, inlet 1" F NPT, outlet 1" F NPT w/ vane |
| PRLV40MF4F4FV | 40 psi, inlet 1" F NPT, outlet 1" F NPT w/ vane |
| PRLV50MF4F4FV | 50 psi, inlet 1" F NPT, outlet 1" F NPT w/ vane |
| PRLV60MF4F4FV | 60 psi, inlet 1" F NPT, outlet 1" F NPT w/ vane |
Specification Charts
Pressure Regulators Comparison (Metric)
* Varies by model, check models chart.
MPR (metric)
| MPR MODELS | Preset Outlet Pressure | Maximum Inlet Pressure | Flow Range | Inlet Sizes | Outlet Sizes |
| MPR152M2F | 1.0 bar | 3.1 bar | 114 - 513 L/hr | 1/2" M NPT | 1/2" F NPT |
| MPR202M2F | 1.4 bar | 3.5 bar | 114 - 559 L/hr | 1/2" M NPT | 1/2" F NPT |
| MPR302M2F | 2.1 bar | 4.1 bar | 136 - 704 L/hr | 1/2" M NPT | 1/2" F NPT |
| MPR402M2F | 2.8 bar | 5.5 bar | 159 - 804 L/hr | 1/2" M NPT | 1/2" F NPT |
The pressure regulator shall maintain the predetermined operating pressure provided that the inlet pressure is at least 5 psi (0.3 bar) above the expected outlet pressure, but not exceeding the maximum inlet pressure as shown above.
Recommended for outdoor use only. Not NSF certified.
PRLG (Metric)
| PRLG DESIGN CRITERIA | Preset Outlet Pressure | Maximum Inlet Pressure | Flow Range | Inlet Sizes | Outlet Sizes |
| PRLG10TLBTLB | 0.69 bar | 1.72 bar | 114 - 1590 L/hr | tape barb (5/8") with lock nuts (green) | tape barb (5/8") with lock nuts (green) |
| PRLG15TLBTLB | 1.03 bar | 1.72 bar | 114 - 1590 L/hr | tape barb (5/8") with lock nuts (green) | tape barb (5/8") with lock nuts (green) |
| PRLG105LB5LB | 0.69 bar | 3.45 bar | 114 - 1590 L/hr | 500 barb (16 mm) with lock nuts (black) | 500 barb (16 mm) with lock nuts (black) |
| PRLG155LB5LB | 1.03 bar | 3.45 bar | 114 - 1590 L/hr | 500 barb (16 mm) with lock nuts (black) | 500 barb (16 mm) with lock nuts (black) |
| PRLG205LB5LB | 1.38 bar | 3.45 bar | 114 - 1590 L/hr | 500 barb (16 mm) with lock nuts (black) | 500 barb (16 mm) with lock nuts (black) |
| PRLG106LB6LB | 0.69 bar | 3.45 bar | 114 - 1590 L/hr | 600 barb (18 mm) with lock nuts (black) | 600 barb (18 mm) with lock nuts (black) |
| PRLG156LB6LB | 1.03 bar | 3.45 bar | 114 - 1590 L/hr | 600 barb (18 mm) with lock nuts (black) | 600 barb (18 mm) with lock nuts (black) |
| PRLG206LB6LB | 1.38 bar | 3.45 bar | 114 - 1590 L/hr | 600 barb (18 mm) with lock nuts (black) | 600 barb (18 mm) with lock nuts (black) |
| PRLG103FH3MH | 0.69 bar | 6.20 bar | 114 - 1590 L/hr | ¾" F hose | ¾" M hose |
| PRLG153FH3MH | 1.03 bar | 6.55 bar | 114 - 1590 L/hr | ¾" F hose | ¾" M hose |
| PRLG203FH3MH | 1.38 bar | 6.89 bar | 114 - 1590 L/hr | ¾" F hose | ¾" M hose |
| PRLG253FH3MH | 1.72 bar | 7.24 bar | 114 - 1590 L/hr | ¾" F hose | ¾" M hose |
| PRLG303FH3MH | 2.07 bar | 7.58 bar | 114 - 1590 L/hr | ¾" F hose | ¾" M hose |
| PRLG353FH3MH | 2.41 bar | 7.93 bar | 114 - 1590 L/hr | ¾" F hose | ¾" M hose |
| PRLG403FH3MH | 2.76 bar | 8.27 bar | 114 - 1590 L/hr | ¾" F hose | ¾" M hose |
| PRLG103F3M | 0.69 bar | 6.20 bar | 114 - 1590 L/hr | ¾" F NPT | ¾" M NPT |
| PRLG153F3M | 1.03 bar | 6.55 bar | 114 - 1590 L/hr | ¾" F NPT | ¾" M NPT |
| PRLG203F3M | 1.38 bar | 6.89 bar | 114 - 1590 L/hr | ¾" F NPT | ¾" M NPT |
| PRLG253F3M | 1.72 bar | 7.24 bar | 114 - 1590 L/hr | ¾" F NPT | ¾" M NPT |
| PRLG303F3M | 2.07 bar | 7.58 bar | 114 - 1590 L/hr | ¾" F NPT | ¾" M NPT |
| PRLG353F3M | 2.41 bar | 7.93 bar | 114 - 1590 L/hr | ¾" F NPT | ¾" M NPT |
| PRLG403F3M | 2.76 bar | 8.27 bar | 114 - 1590 L/hr | ¾" F NPT | ¾" M NPT |
The pressure regulator shall maintain the predetermined operating pressure provided that the inlet pressure is at least 0.34 bar above the expected outlet pressure, but not exceeding the maximum inlet pressure as shown above.
Recommended for outdoor use only. Not NSF certified.
PRMP(Metric)
| PRMP DESIGN CRITERIA | Preset Operating Pressure | Maximum Inlet Pressure | Flow Range | Inlet Sizes | Outlet Sizes |
| PRMP103FH3MH | 0.69 bar | 6.20 bar | 114 - 1590 L/hr | 3/4" F hose | 3/4" M hose |
| PRMP153FH3MH | 1.03 bar | 6.55 bar | 114 - 1590 L/hr | 3/4" F hose | 3/4" M hose |
| PRMP203FH3MH | 1.38 bar | 6.89 bar | 114 - 1590 L/hr | 3/4" F hose | 3/4" M hose |
| PRMP253FH3MH | 1.72 bar | 7.24 bar | 114 - 1590 L/hr | 3/4" F hose | 3/4" M hose |
| PRMP303FH3MH | 2.07 bar | 7.58 bar | 114 - 1590 L/hr | 3/4" F hose | 3/4" M hose |
| PRMP353FH3MH | 2.41 bar | 7.93 bar | 114 - 1590 L/hr | 3/4" F hose | 3/4" M hose |
| PRMP403FH3MH | 2.76 bar | 8.27 bar | 114 - 1590 L/hr | 3/4" F hose | 3/4" M hose |
| PRMP103F3M | 0.69 bar | 6.20 bar | 114 - 1590 L/hr | 3/4" F NPT | 3/4" M NPT |
| PRMP153F3M | 1.03 bar | 6.55 bar | 114 - 1590 L/hr | 3/4" F NPT | 3/4" M NPT |
| PRMP203F3M | 1.38 bar | 6.89 bar | 114 - 1590 L/hr | 3/4" F NPT | 3/4" M NPT |
| PRMP253F3M | 1.72 bar | 7.24 bar | 114 - 1590 L/hr | 3/4" F NPT | 3/4" M NPT |
| PRMP303F3M | 2.07 bar | 7.58 bar | 114 - 1590 L/hr | 3/4" F NPT | 3/4" M NPT |
| PRMP353F3M | 2.41 bar | 7.93 bar | 114 - 1590 L/hr | 3/4" F NPT | 3/4" M NPT |
| PRMP403F3M | 2.76 bar | 8.27 bar | 114 - 1590 L/hr | 3/4" F NPT | 3/4" M NPT |
| PRMP10TLBTLB | 0.69 bar | 1.72 bar | 114 - 1590 L/hr | tape (5/8") | tape (5/8") |
| PRMP15TLBTLB | 1.03 bar | 1.72 bar | 114 - 1590 L/hr | tape (5/8") | tape (5/8") |
| PRMP105LB5LB | 0.69 bar | 3.45 bar | 114 - 1590 L/hr | 500 (16 mm) | 500 (16 mm) |
| PRMP155LB5LB | 1.03 bar | 3.45 bar | 114 - 1590 L/hr | 500 (16 mm) | 500 (16 mm) |
| PRMP205LB5LB | 1.38 bar | 3.45 bar | 114 - 1590 L/hr | 500 (16 mm) | 500 (16 mm) |
| PRMP106LB6LB | 0.69 bar | 3.45 bar | 114 - 1590 L/hr | 600 (18 mm) | 600 (18 mm) |
| PRMP156LB6LB | 1.03 bar | 3.45 bar | 114 - 1590 L/hr | 600 (18 mm) | 600 (18 mm) |
| PRMP2056LB6LB | 1.38 bar | 3.45 bar | 114 - 1590 L/hr | 600 (18 mm) | 600 (18 mm) |
The pressure regulator shall maintain the predetermined operating pressure provided that the inlet pressure is at least 0.34 bar above the expected outlet pressure, but not exceeding the maximum inlet pressure as shown above.
PRL (Metric)
| PRL MODELS | Preset Outlet Pressure | Maximum Inlet Pressure | Flow Range | Inlet Sizes | Outlet Sizes |
| PRL06 | 0.41 bar | 5.51 bar | 114 - 1136 L/hr | 3/4" F NPT, 3/4" F hose | 3/4" F NPT |
| PRL10 | 0.69 bar | 6.20 bar | 114 - 1817 L/hr | 3/4" F NPT, 3/4" F hose | 3/4" F NPT |
| PRL12 | 0.83 bar | 6.20 bar | 114 - 1817 L/hr | 3/4" F NPT, 3/4" F hose | 3/4" F NPT |
| PRL15 | 1.03 bar | 6.55 bar | 114 - 1817 L/hr | 3/4" F NPT, 3/4" F hose | 3/4" F NPT |
| PRL20 | 1.38 bar | 6.89 bar | 114 - 1817 L/hr | 3/4" F NPT, 3/4" F hose | 3/4" F NPT |
| PRL25 | 1.72 bar | 7.24 bar | 114 - 1817 L/hr | 3/4" F NPT, 3/4" F hose | 3/4" F NPT |
| PRL30 | 2.07 bar | 7.58 bar | 114 - 1817 L/hr | 3/4" F NPT, 3/4" F hose | 3/4" F NPT |
| PRL35 | 2.41 bar | 7.93 bar | 114 - 1817 L/hr | 3/4" F NPT, 3/4" F hose | 3/4" F NPT |
| PRL40 | 2.76 bar | 8.27 bar | 114 - 1817 L/hr | 3/4" F NPT, 3/4" F hose | 3/4" F NPT |
The pressure regulator shall maintain the predetermined operating pressure provided that the inlet pressure is at least 5 psi (0.34 bar) above the expected outlet pressure, but not exceeding the maximum inlet pressure as shown above.
Recommended for outdoor use only. Not NSF certified.
PSR™2 (Metric)
| PSR2 MODELS | Preset Outlet Pressure | Maximum Inlet Pressure | Flow Range | Inlet Sizes | Outlet Sizes |
| PSR2 06 | 0.41 bar | 5.51 bar | 114 - 3407 L/hr | 3/4" F NPT | 3/4" F NPT |
| PSR2 10 | 0.69 bar | 6.20 bar | 114 - 3407 L/hr | 3/4" F NPT | 3/4" F NPT |
| PSR2 12 | 0.83 bar | 6.20 bar | 114 - 3407 L/hr | 3/4" F NPT | 3/4" F NPT |
| PSR2 15 | 1.03 bar | 6.55 bar | 114 - 3407 L/hr | 3/4" F NPT | 3/4" F NPT |
| PSR2 20 | 1.38 bar | 6.89 bar | 114 - 3407 L/hr | 3/4" F NPT | 3/4" F NPT |
| PSR2 25 | 1.72 bar | 7.24 bar | 114 - 3407 L/hr | 3/4" F NPT | 3/4" F NPT |
| PSR2 30 | 2.07 bar | 7.58 bar | 114 - 3407 L/hr | 3/4" F NPT | 3/4" F NPT |
| PSR2 35 | 2.41 bar | 7.93 bar | 114 - 3407 L/hr | 3/4" F NPT | 3/4" F NPT |
| PSR2 40 | 2.76 bar | 8.27 bar | 114 - 3407 L/hr | 3/4" F NPT | 3/4" F NPT |
| PSR2 50 | 3.45 bar | 8.96 bar | 114 - 3407 L/hr | 3/4" F NPT | 3/4" F NPT |
The pressure regulator shall maintain the predetermined operating pressure provided that the inlet pressure is at least 5 psi (0.34 bar) above the expected outlet pressure, but not exceeding the maximum inlet pressure as shown above.
Recommended for outdoor use only. Not NSF certified.
Filter Regulator (Metric)
| FILTER REGULATOR MODELS | Preset Outlet Pressure | Maximum Inlet Pressure | Mesh Filter Screen | Mesh Orifice (microns) | UP3 Nozzle Number |
| FPSR2063M3F20 | 0.41 bar | 5.51 bar | 20 mesh (black rings) | 841 | #13 - #26 |
| FPSR2063M3F30 | 30 mesh (green rings) | 595 | #6 - #12.5 | ||
| FPSR2063M3F40 | 40 mesh (grey rings) | 400 | #2 - #5.5 | ||
| FPSR2103M3F20 | 0.69 bar | 6.20 bar | 20 mesh (black rings) | 841 | #13 - #26 |
| FPSR2103M3F30 | 30 mesh (green rings) | 595 | #6 - #12.5 | ||
| FPSR2103M3F40 | 40 mesh (grey rings) | 400 | #2 - #5.5 | ||
| FPSR2153M3F20 | 1.03 bar | 6.55 bar | 20 mesh (black rings) | 841 | #13 - #26 |
| FPSR2153M3F30 | 30 mesh (green rings) | 595 | #6 - #12.5 | ||
| FPSR2153M3F40 | 40 mesh (grey rings) | 400 | #2 - #5.5 | ||
| FPSR2203M3F20 | 1.38 bar | 6.89 bar | 20 mesh (black rings) | 841 | #13 - #26 |
| FPSR2203M3F30 | 30 mesh (green rings) | 595 | #6 - #12.5 | ||
| FPSR2203M3F40 | 40 mesh (grey rings) | 400 | #2 - #5.5 | ||
| FPSR2103M3F120 | 0.69 bar | 6.20 bar | 120 mesh screen (red rings) | 125 | 1140 - 3407 L/hr |
| FPSR2103M3F140 | 140 mesh screen (blue rings) | 105 | |||
| FPSR2153M3F120 | 1.03 bar | 6.55 bar | 120 mesh screen (red rings) | 125 | 1140 - 3407 L/hr |
| FPSR2153M3F140 | 140 mesh screen (blue rings) | 105 | |||
| FPSR2203M3F120 | 1.38 bar | 6.89 bar | 120 mesh screen (red rings) | 125 | 1140 - 3407 L/hr |
| FPSR2203M3F140 | 140 mesh screen (blue rings) | 105 | |||
Shaded models designed for use with drip systems.
The pressure regulator shall maintain the predetermined operating pressure provided that the inlet pressure is at least 5 psi (0.34 bar) above the expected outlet pressure, with flows up to 11 gpm (2498 L/hr), but not exceeding the maximum inlet pressure of 80 psi (5.5 bar) above the model’s pressure rating. Higher flows require additional inlet pressure to engage the regulator. Where flows are greater than 11 gpm (2498 L/hr), the inlet pressure should be at least 9 psi (0.62 bar) above the expected outlet pressure but not exceeding the maximum inlet pressure as shown above.
Pressure regulators should always be installed downstream of all shut-off valves.
Recommended for outdoor use only. Not NSF certified.
PMR-MF (Metric)
| PMR-MF MODELS | Preset Outlet Pressure | Maximum Inlet Pressure | Flow Range | Inlet Sizes | Outlet Sizes |
| PMR06MF | 0.41 bar | 5.51 bar | 909 - 3634 L/hr | 3/4" F NPT, 1" F NPT, 1" F BSPT | 3/4" F NPT, 1" F NPT, 1" F BSPT |
| PMR10MF | 0.69 bar | 6.20 bar | 909 - 3634 L/hr | 3/4" F NPT, 1" F NPT, 1" F BSPT | 3/4" F NPT, 1" F NPT, 1" F BSPT |
| PMR12MF | 0.83 bar | 6.20 bar | 454 - 4543 L/hr | 3/4" F NPT, 1" F NPT, 1" F BSPT | 3/4" F NPT, 1" F NPT, 1" F BSPT |
| PMR15MF | 1.03 bar | 6.55 bar | 454 - 4543 L/hr | 3/4" F NPT, 1" F NPT, 1" F BSPT | 3/4" F NPT, 1" F NPT, 1" F BSPT |
| PMR20MF | 1.38 bar | 6.89 bar | 454 - 4543 L/hr | 3/4" F NPT, 1" F NPT, 1" F BSPT | 3/4" F NPT, 1" F NPT, 1" F BSPT |
| PMR25MF | 1.72 bar | 7.24 bar | 454 - 4543 L/hr | 3/4" F NPT, 1" F NPT, 1" F BSPT | 3/4" F NPT, 1" F NPT, 1" F BSPT |
| PMR30MF | 2.07 bar | 7.58 bar | 454 - 4543 L/hr | 3/4" F NPT, 1" F NPT, 1" F BSPT | 3/4" F NPT, 1" F NPT, 1" F BSPT |
| PMR35MF | 2.41 bar | 7.93 bar | 454 - 4543 L/hr | 3/4" F NPT, 1" F NPT, 1" F BSPT | 3/4" F NPT, 1" F NPT, 1" F BSPT |
| PMR40MF | 2.76 bar | 8.27 bar | 454 - 4543 L/hr | 3/4" F NPT, 1" F NPT, 1" F BSPT | 3/4" F NPT, 1" F NPT, 1" F BSPT |
| PMR50MF | 3.45 bar | 8.96 bar | 454 - 4543 L/hr | 3/4" F NPT, 1" F NPT, 1" F BSPT | 3/4" F NPT, 1" F NPT, 1" F BSPT |
| PMR60MF | 4.14 bar | 9.65 bar | 454 - 4543 L/hr | 3/4" F NPT, 1" F NPT, 1" F BSPT | 3/4" F NPT, 1" F NPT, 1" F BSPT |
The pressure regulator shall maintain the predetermined operating pressure provided that the inlet pressure is at least 5 psi (0.34 bar) above the expected outlet pressure, but not exceeding the maximum inlet pressure as shown above.
Recommended for outdoor use only. Not NSF certified.
PR-HF (Metric)
| PR-HF MODELS | Preset Outlet Pressure | Maximum Inlet Pressure | Flow Range | Inlet Sizes | Outlet Sizes |
| PR10HF | 0.69 bar | 6.20 bar | 2271 - 7268 L/hr | 1¼" F NPT, 1¼" F BSPT | 1" F NPT, 1¼" F NPT, 1" F BSPT, 1¼" F BSPT |
| PR15HF | 1.03 bar | 6.55 bar | 2271 - 7268 L/hr | 1¼" F NPT, 1¼" F BSPT | 1" F NPT, 1¼" F NPT, 1" F BSPT, 1¼" F BSPT |
| PR20HF | 1.38 bar | 6.89 bar | 2271 - 7268 L/hr | 1¼" F NPT, 1¼" F BSPT | 1" F NPT, 1¼" F NPT, 1" F BSPT, 1¼" F BSPT |
| PR25HF | 1.72 bar | 7.24 bar | 2271 - 7268 L/hr | 1¼" F NPT, 1¼" F BSPT | 1" F NPT, 1¼" F NPT, 1" F BSPT, 1¼" F BSPT |
| PR30HF | 2.07 bar | 7.58 bar | 2271 - 7268 L/hr | 1¼" F NPT, 1¼" F BSPT | 1" F NPT, 1¼" F NPT, 1" F BSPT, 1¼" F BSPT |
| PR40HF | 2.76 bar | 8.27 bar | 2271 - 7268 L/hr | 1¼" F NPT, 1¼" F BSPT | 1" F NPT, 1¼" F NPT, 1" F BSPT, 1¼" F BSPT |
| PR50HF | 3.45 bar | 8.96 bar | 2271 - 7268 L/hr | 1¼" F NPT, 1¼" F BSPT | 1" F NPT, 1¼" F NPT, 1" F BSPT, 1¼" F BSPT |
The pressure regulator shall maintain the predetermined operating pressure provided that the inlet pressure is at least 5 psi (0.34 bar) above the expected outlet pressure, but not exceeding the maximum inlet pressure as shown above.
Recommended for outdoor use only. Not NSF certified.
PRU (Metric)
| PRU MODELS | Preset Outlet Pressure | Maximum Inlet Pressure | Flow Range | Inlet Sizes | Outlet Sizes |
| PRU10 | 0.69 bar | 6.20 bar | 4543 - 22713 L/hr | 2" F NPT, 2" F BSPT | 2" F NPT, 2" F BSPT |
| PRU15 | 1.03 bar | 6.55 bar | 4543 - 22713 L/hr | 2" F NPT, 2" F BSPT | 2" F NPT, 2" F BSPT |
| PRU20 | 1.38 bar | 6.89 bar | 4543 - 22713 L/hr | 2" F NPT, 2" F BSPT | 2" F NPT, 2" F BSPT |
| PRU25 | 1.72 bar | 7.24 bar | 4543 - 22713 L/hr | 2" F NPT, 2" F BSPT | 2" F NPT, 2" F BSPT |
| PRU30 | 2.07 bar | 7.58 bar | 4543 - 22713 L/hr | 2" F NPT, 2" F BSPT | 2" F NPT, 2" F BSPT |
| PRU40 | 2.76 bar | 8.27 bar | 4543 - 22713 L/hr | 2" F NPT, 2" F BSPT | 2" F NPT, 2" F BSPT |
| PRU50 | 3.45 bar | 8.96 bar | 4543 - 22713 L/hr | 2" F NPT, 2" F BSPT | 2" F NPT, 2" F BSPT |
| PRU60 | 4.14 bar | 9.65 bar | 4543 - 22713 L/hr | 2" F NPT, 2" F BSPT | 2" F NPT, 2" F BSPT |
The pressure regulator shall maintain the predetermined operating pressure provided that the inlet pressure is at least 5 psi (0.34 bar) above the expected outlet pressure, but not exceeding the maximum inlet pressure as shown above.
Recommended for outdoor use only. Not NSF certified.
PRU-LV (Metric)
| PRU-LV MODELS | Preset Outlet Pressure | Maximum Inlet Pressure | Flow Range | Inlet Sizes | Outlet Sizes |
| PRU LV 10 | 0.69 bar | 8.62 bar | up to 22713 L/hr | 2" F NPT, 2" F BSPT | 2" F NPT, 2" F BSPT |
| PRU LV 15 | 1.03 bar | 8.62 bar | up to 22713 L/hr | 2" F NPT, 2" F BSPT | 2" F NPT, 2" F BSPT |
| PRU LV 20 | 1.38 bar | 8.62 bar | up to 22713 L/hr | 2" F NPT, 2" F BSPT | 2" F NPT, 2" F BSPT |
| PRU LV 25 | 1.72 bar | 8.62 bar | up to 22713 L/hr | 2" F NPT, 2" F BSPT | 2" F NPT, 2" F BSPT |
| PRU LV 30 | 2.07 bar | 8.62 bar | up to 22713 L/hr | 2" F NPT, 2" F BSPT | 2" F NPT, 2" F BSPT |
| PRU LV 40 | 2.76 bar | 8.62 bar | up to 22713 L/hr | 2" F NPT, 2" F BSPT | 2" F NPT, 2" F BSPT |
| PRU LV 50 | 3.45 bar | 8.62 bar | up to 22713 L/hr | 2" F NPT, 2" F BSPT | 2" F NPT, 2" F BSPT |
| PRU LV 60 | 4.14 bar | 8.62 bar | up to 22713 L/hr | 2" F NPT, 2" F BSPT | 2" F NPT, 2" F BSPT |
The PRU-LV limits downstream pressure to no more than 1.03 bar above regulated pressure during static (no flow) conditions.
Recommended for outdoor use only. Not NSF certified.
PRLV (Metric)
| PRLV MODELS | Preset Outlet Pressure | Maximum Inlet Pressure | Maximum Flow | Inlet Sizes | Outlet Sizes |
| PRLV10 | 0.69 bar | 8.62 bar | 4088 L/hr | 3/4" F NPT, 1" F NPT | 3/4" F NPT, 1" F NPT |
| PRLV15 | 1.03 bar | 8.62 bar | 4088 L/hr | 3/4" F NPT, 1" F NPT | 3/4" F NPT, 1" F NPT |
| PRLV20 | 1.38 bar | 8.62 bar | 4088 L/hr | 3/4" F NPT, 1" F NPT | 3/4" F NPT, 1" F NPT |
| PRLV30 | 2.07 bar | 8.62 bar | 4088 L/hr | 3/4" F NPT, 1" F NPT | 3/4" F NPT, 1" F NPT |
| PRLV40 | 2.76 bar | 8.62 bar | 4088 L/hr | 3/4" F NPT, 1" F NPT | 3/4" F NPT, 1" F NPT |
| PRLV50 | 3.45 bar | 8.62 bar | 4088 L/hr | 3/4" F NPT, 1" F NPT | 3/4" F NPT, 1" F NPT |
| PRLV60 | 4.14 bar | 8.62 bar | 4088 L/hr | 3/4" F NPT, 1" F NPT | 3/4" F NPT, 1" F NPT |
The PRLV limits downstream pressure to no more than 15 psi (1.03 bar) above regulated pressure during static (no flow) conditions.
Recommended for outdoor use only. Not NSF certified.