Inlet Sizes:
3/4" female NPT, 1" female NPT
Oulet Sizes:
3/4" female NPT, 1" female NPT

Operating Specifications

Pressures:
0.69 - 4.14 bar
Flows:
up to 4088 L/hr

Additional Information

PRLV Models
Part NumberDescription
3/4" x 3/4" NPT models 
PRLV10MF3F3FV10 psi, inlet 3/4" F NPT, outlet 3/4" F NPT w/ vane
PRLV15MF3F3FV15 psi, inlet 3/4" F NPT, outlet 3/4" F NPT w/ vane
PRLV20MF3F3FV20 psi, inlet 3/4" F NPT, outlet 3/4" F NPT w/ vane
PRLV30MF3F3FV30 psi, inlet 3/4" F NPT, outlet 3/4" F NPT w/ vane
PRLV40MF3F3FV40 psi, inlet 3/4" F NPT, outlet 3/4" F NPT w/ vane
PRLV50MF3F3FV50 psi, inlet 3/4" F NPT, outlet 3/4" F NPT w/ vane
PRLV60MF3F3FV60 psi, inlet 3/4" F NPT, outlet 3/4" F NPT w/ vane
1" x 1" NPT models 
PRLV10MF4F4FV10 psi, inlet 1" F NPT, outlet 1" F NPT w/ vane
PRLV15MF4F4FV15 psi, inlet 1" F NPT, outlet 1" F NPT w/ vane
PRLV20MF4F4FV20 psi, inlet 1" F NPT, outlet 1" F NPT w/ vane
PRLV30MF4F4FV30 psi, inlet 1" F NPT, outlet 1" F NPT w/ vane
PRLV40MF4F4FV40 psi, inlet 1" F NPT, outlet 1" F NPT w/ vane
PRLV50MF4F4FV50 psi, inlet 1" F NPT, outlet 1" F NPT w/ vane
PRLV60MF4F4FV60 psi, inlet 1" F NPT, outlet 1" F NPT w/ vane

Specification Charts

Pressure Regulators Comparison (Metric)

 ModelMarketPreset
Outlet
Pressure
Maximum
Inlet
Pressure*
Flow
Range
Inlet
Sizes
Outlet
Sizes
MPRSolid Set/
Nursery
1.0 -
2.8 bar
5.5 bar114 -
804 L/hr
1/2" M NPT1/2" F NPT
PRLGSolid Set/
Nursery
0.69 -
2.76 bar
8.27 bar114 -
1590 L/hr
3/4" F hose,
3/4" F NPT,
tape lock barb (5/8"),
500 lock barb (16 mm),
600 lock barb (18 mm)
3/4" M hose,
3/4" M NPT,
tape lock barb (5/8"),
500 lock barb (16 mm),
600 lock barb (18 mm)
PRMPSolution Mining0.69 -
2.76 bar
 114 -
1590 L/hr
3/4" F hose,
3/4" F NPT,
tape (5/8"),
500 (16 mm),
600 (18 mm)
3/4" F hose,
3/4" F NPT,
tape (5/8"),
500 (16 mm),
600 (18 mm)
PRLPivot0.41 -
2.76 bar
8.27 bar114 -
1817 L/hr
3/4" F NPT,
3/4" F hose
3/4" F NPT
Solid Set/
Nursery
Solution Mining
PSR-2Pivot0.41 -
3.45 bar
8.96 bar114 -
3407 L/hr
3/4" F NPT3/4" F NPT
Solid Set/
Nursery
Filter RegulatorPivot0.41 -
3.45 bar
8.96 bar114 -
3407 L/hr
3/4" M NPT3/4" F NPT
Solid Set/
Nursery
PMR-MFPivot0.41 -
4.14 bar
9.65 bar454 -
4543 L/hr
3/4" F NPT,
1" F NPT,
1" F BSPT
3/4" F NPT,
1" F NPT,
1" F BSPT
Solid Set/
Nursery
Solution Mining
PR-HFSolid Set/
Nursery
0.69 -
3.45 bar
8.96 bar2271 -
7268 L/hr
1-1/4" F NPT,
1-1/4" F BSPT
1" F NPT,
1-1/4" F NPT,
1" F BSPT,
1-1/4" F BSPT
PRUSolid Set/
Nursery
0.41 -
4.14 bar
9.65 bar4543 -
22713 L/hr
2" F NPT,
2" F BSPT
2" F NPT,
2" F BSPT
PRLVSolid Set/
Nursery
0.69 -
4.14 bar
8.62 barup to
4088 L/hr
3/4" F NPT,
1" F NPT
3/4" F NPT,
1" F NPT
PRU-LVSolid Set/
Nursery
0.69 -
4.14 bar
8.62 barMax: 22713 L/hr2" F NPT,
2" F BSPT
2" F NPT,
2" F BSPT

* Varies by model, check models chart.

MPR (metric)

MPR
MODELS
Preset 
Outlet Pressure
Maximum Inlet PressureFlow RangeInlet SizesOutlet Sizes
MPR152M2F1.0 bar3.1 bar114 - 513 L/hr1/2" M NPT1/2" F NPT
MPR202M2F1.4 bar3.5 bar114 - 559 L/hr1/2" M NPT1/2" F NPT
MPR302M2F2.1 bar4.1 bar136 - 704 L/hr1/2" M NPT1/2" F NPT
MPR402M2F2.8 bar5.5 bar159 - 804 L/hr1/2" M NPT1/2" F NPT

The pressure regulator shall maintain the predetermined operating pressure provided that the inlet pressure is at least 5 psi (0.3 bar) above the expected outlet pressure, but not exceeding the maximum inlet pressure as shown above.

Recommended for outdoor use only. Not NSF certified.

PRLG (Metric)

PRLG
DESIGN CRITERIA
Preset Outlet PressureMaximum Inlet PressureFlow RangeInlet SizesOutlet Sizes
PRLG10TLBTLB0.69 bar1.72 bar114 - 1590 L/hrtape barb (5/8")
with lock nuts (green)
tape barb (5/8")
with lock nuts (green)
PRLG15TLBTLB1.03 bar1.72 bar114 - 1590 L/hrtape barb (5/8")
with lock nuts (green)
tape barb (5/8")
with lock nuts (green)
      
PRLG105LB5LB0.69 bar3.45 bar114 - 1590 L/hr500 barb (16 mm)
with lock nuts (black)
500 barb (16 mm)
with lock nuts (black)
PRLG155LB5LB1.03 bar3.45 bar114 - 1590 L/hr500 barb (16 mm)
with lock nuts (black)
500 barb (16 mm)
with lock nuts (black)
PRLG205LB5LB1.38 bar3.45 bar114 - 1590 L/hr500 barb (16 mm)
with lock nuts (black)
500 barb (16 mm)
with lock nuts (black)
      
PRLG106LB6LB0.69 bar3.45 bar114 - 1590 L/hr600 barb (18 mm)
with lock nuts (black)
600 barb (18 mm)
with lock nuts (black)
PRLG156LB6LB1.03 bar3.45 bar114 - 1590 L/hr600 barb (18 mm)
with lock nuts (black)
600 barb (18 mm)
with lock nuts (black)
PRLG206LB6LB1.38 bar3.45 bar114 - 1590 L/hr600 barb (18 mm)
with lock nuts (black)
600 barb (18 mm)
with lock nuts (black)
      
PRLG103FH3MH0.69 bar6.20 bar114 - 1590 L/hr¾" F hose¾" M hose
PRLG153FH3MH1.03 bar6.55 bar114 - 1590 L/hr¾" F hose¾" M hose
PRLG203FH3MH1.38 bar6.89 bar114 - 1590 L/hr¾" F hose¾" M hose
PRLG253FH3MH1.72 bar7.24 bar114 - 1590 L/hr¾" F hose¾" M hose
PRLG303FH3MH2.07 bar7.58 bar114 - 1590 L/hr¾" F hose¾" M hose
PRLG353FH3MH2.41 bar7.93 bar114 - 1590 L/hr¾" F hose¾" M hose
PRLG403FH3MH2.76 bar8.27 bar114 - 1590 L/hr¾" F hose¾" M hose
      
PRLG103F3M0.69 bar6.20 bar114 - 1590 L/hr¾" F NPT¾" M NPT
PRLG153F3M1.03 bar6.55 bar114 - 1590 L/hr¾" F NPT¾" M NPT
PRLG203F3M1.38 bar6.89 bar114 - 1590 L/hr¾" F NPT¾" M NPT
PRLG253F3M1.72 bar7.24 bar114 - 1590 L/hr¾" F NPT¾" M NPT
PRLG303F3M2.07 bar7.58 bar114 - 1590 L/hr¾" F NPT¾" M NPT
PRLG353F3M2.41 bar7.93 bar114 - 1590 L/hr¾" F NPT¾" M NPT
PRLG403F3M2.76 bar8.27 bar114 - 1590 L/hr¾" F NPT¾" M NPT

The pressure regulator shall maintain the predetermined operating pressure provided that the inlet pressure is at least 0.34 bar above the expected outlet pressure, but not exceeding the maximum inlet pressure as shown above.

Recommended for outdoor use only. Not NSF certified.

PRMP(Metric)

PRMP
DESIGN CRITERIA
Preset Operating PressureMaximum Inlet PressureFlow RangeInlet SizesOutlet Sizes
PRMP103FH3MH0.69 bar6.20 bar114 - 1590 L/hr3/4" F hose3/4" M hose
PRMP153FH3MH1.03 bar6.55 bar114 - 1590 L/hr3/4" F hose3/4" M hose
PRMP203FH3MH1.38 bar6.89 bar114 - 1590 L/hr3/4" F hose3/4" M hose
PRMP253FH3MH1.72 bar7.24 bar114 - 1590 L/hr3/4" F hose3/4" M hose
PRMP303FH3MH2.07 bar7.58 bar114 - 1590 L/hr3/4" F hose3/4" M hose
PRMP353FH3MH2.41 bar7.93 bar114 - 1590 L/hr3/4" F hose3/4" M hose
PRMP403FH3MH2.76 bar8.27 bar114 - 1590 L/hr3/4" F hose3/4" M hose
      
PRMP103F3M0.69 bar6.20 bar114 - 1590 L/hr3/4" F NPT3/4" M NPT
PRMP153F3M1.03 bar6.55 bar114 - 1590 L/hr3/4" F NPT3/4" M NPT
PRMP203F3M1.38 bar6.89 bar114 - 1590 L/hr3/4" F NPT3/4" M NPT
PRMP253F3M1.72 bar7.24 bar114 - 1590 L/hr3/4" F NPT3/4" M NPT
PRMP303F3M2.07 bar7.58 bar114 - 1590 L/hr3/4" F NPT3/4" M NPT
PRMP353F3M2.41 bar7.93 bar114 - 1590 L/hr3/4" F NPT3/4" M NPT
PRMP403F3M2.76 bar8.27 bar114 - 1590 L/hr3/4" F NPT3/4" M NPT
      
PRMP10TLBTLB0.69 bar1.72 bar114 - 1590 L/hrtape (5/8")tape (5/8")
PRMP15TLBTLB1.03 bar1.72 bar114 - 1590 L/hrtape (5/8")tape (5/8")
      
PRMP105LB5LB0.69 bar3.45 bar114 - 1590 L/hr500 (16 mm)500 (16 mm)
PRMP155LB5LB1.03 bar3.45 bar114 - 1590 L/hr500 (16 mm)500 (16 mm)
PRMP205LB5LB1.38 bar3.45 bar114 - 1590 L/hr500 (16 mm)500 (16 mm)
      
PRMP106LB6LB0.69 bar3.45 bar114 - 1590 L/hr600 (18 mm)600 (18 mm)
PRMP156LB6LB1.03 bar3.45 bar114 - 1590 L/hr600 (18 mm)600 (18 mm)
PRMP2056LB6LB1.38 bar3.45 bar114 - 1590 L/hr600 (18 mm)600 (18 mm)

The pressure regulator shall maintain the predetermined operating pressure provided that the inlet pressure is at least 0.34 bar above the expected outlet pressure, but not exceeding the maximum inlet pressure as shown above.

PRL (Metric)

PRL
MODELS
Preset Outlet PressureMaximum Inlet PressureFlow RangeInlet SizesOutlet Sizes
PRL060.41 bar5.51 bar114 - 1136 L/hr3/4" F NPT, 3/4" F hose3/4" F NPT
PRL100.69 bar6.20 bar114 - 1817 L/hr3/4" F NPT, 3/4" F hose3/4" F NPT
PRL120.83 bar6.20 bar114 - 1817 L/hr3/4" F NPT, 3/4" F hose3/4" F NPT
PRL151.03 bar6.55 bar114 - 1817 L/hr3/4" F NPT, 3/4" F hose3/4" F NPT
PRL201.38 bar6.89 bar114 - 1817 L/hr3/4" F NPT, 3/4" F hose3/4" F NPT
PRL251.72 bar7.24 bar114 - 1817 L/hr3/4" F NPT, 3/4" F hose3/4" F NPT
PRL302.07 bar7.58 bar114 - 1817 L/hr3/4" F NPT, 3/4" F hose3/4" F NPT
PRL352.41 bar7.93 bar114 - 1817 L/hr3/4" F NPT, 3/4" F hose3/4" F NPT
PRL402.76 bar8.27 bar114 - 1817 L/hr3/4" F NPT, 3/4" F hose3/4" F NPT

The pressure regulator shall maintain the predetermined operating pressure provided that the inlet pressure is at least 5 psi (0.34 bar) above the expected outlet pressure, but not exceeding the maximum inlet pressure as shown above.

Recommended for outdoor use only. Not NSF certified.

PSR™2 (Metric)

PSR2
MODELS
Preset Outlet PressureMaximum Inlet PressureFlow RangeInlet SizesOutlet Sizes
PSR2 060.41 bar5.51 bar114 - 3407 L/hr3/4" F NPT3/4" F NPT
PSR2 100.69 bar6.20 bar114 - 3407 L/hr3/4" F NPT3/4" F NPT
PSR2 120.83 bar6.20 bar114 - 3407 L/hr3/4" F NPT3/4" F NPT
PSR2 151.03 bar6.55 bar114 - 3407 L/hr3/4" F NPT3/4" F NPT
PSR2 201.38 bar6.89 bar114 - 3407 L/hr3/4" F NPT3/4" F NPT
PSR2 251.72 bar7.24 bar114 - 3407 L/hr3/4" F NPT3/4" F NPT
PSR2 302.07 bar7.58 bar114 - 3407 L/hr3/4" F NPT3/4" F NPT
PSR2 352.41 bar7.93 bar114 - 3407 L/hr3/4" F NPT3/4" F NPT
PSR2 402.76 bar8.27 bar114 - 3407 L/hr3/4" F NPT3/4" F NPT
PSR2 503.45 bar8.96 bar114 - 3407 L/hr3/4" F NPT3/4" F NPT

The pressure regulator shall maintain the predetermined operating pressure provided that the inlet pressure is at least 5 psi (0.34 bar) above the expected outlet pressure, but not exceeding the maximum inlet pressure as shown above.

Recommended for outdoor use only. Not NSF certified.

Filter Regulator (Metric)

FILTER REGULATOR
MODELS
Preset Outlet
Pressure
Maximum Inlet
Pressure
Mesh Filter ScreenMesh Orifice
(microns)
UP3 Nozzle
Number
FPSR2063M3F200.41 bar5.51 bar20 mesh (black rings)841#13 - #26
FPSR2063M3F3030 mesh (green rings)595#6 - #12.5
FPSR2063M3F4040 mesh (grey rings)400#2 - #5.5
FPSR2103M3F200.69 bar6.20 bar20 mesh (black rings)841#13 - #26
FPSR2103M3F3030 mesh (green rings)595#6 - #12.5
FPSR2103M3F4040 mesh (grey rings)400#2 - #5.5
FPSR2153M3F201.03 bar6.55 bar20 mesh (black rings)841#13 - #26
FPSR2153M3F3030 mesh (green rings)595#6 - #12.5
FPSR2153M3F4040 mesh (grey rings)400#2 - #5.5
FPSR2203M3F201.38 bar6.89 bar20 mesh (black rings)841#13 - #26
FPSR2203M3F3030 mesh (green rings)595#6 - #12.5
FPSR2203M3F4040 mesh (grey rings)400#2 - #5.5
 
FPSR2103M3F1200.69 bar6.20 bar120 mesh screen (red rings)1251140 - 3407 L/hr
FPSR2103M3F140140 mesh screen (blue rings)105
FPSR2153M3F1201.03 bar6.55 bar120 mesh screen (red rings)1251140 - 3407 L/hr
FPSR2153M3F140140 mesh screen (blue rings)105
FPSR2203M3F1201.38 bar6.89 bar120 mesh screen (red rings)1251140 - 3407 L/hr
FPSR2203M3F140140 mesh screen (blue rings)105

Shaded models designed for use with drip systems.

The pressure regulator shall maintain the predetermined operating pressure provided that the inlet pressure is at least 5 psi (0.34 bar) above the expected outlet pressure, with flows up to 11 gpm (2498 L/hr), but not exceeding the maximum inlet pressure of 80 psi (5.5 bar) above the model’s pressure rating. Higher flows require additional inlet pressure to engage the regulator. Where flows are greater than 11 gpm (2498 L/hr), the inlet pressure should be at least 9 psi (0.62 bar) above the expected outlet pressure but not exceeding the maximum inlet pressure as shown above.

Pressure regulators should always be installed downstream of all shut-off valves.

Recommended for outdoor use only. Not NSF certified.

PMR-MF (Metric)

PMR-MF
MODELS
Preset Outlet PressureMaximum Inlet PressureFlow RangeInlet SizesOutlet Sizes
PMR06MF0.41 bar5.51 bar909 - 3634 L/hr3/4" F NPT, 1" F NPT, 1" F BSPT3/4" F NPT, 1" F NPT, 1" F BSPT
PMR10MF0.69 bar6.20 bar909 - 3634 L/hr3/4" F NPT, 1" F NPT, 1" F BSPT3/4" F NPT, 1" F NPT, 1" F BSPT
PMR12MF0.83 bar6.20 bar454 - 4543 L/hr3/4" F NPT, 1" F NPT, 1" F BSPT3/4" F NPT, 1" F NPT, 1" F BSPT
PMR15MF1.03 bar6.55 bar454 - 4543 L/hr3/4" F NPT, 1" F NPT, 1" F BSPT3/4" F NPT, 1" F NPT, 1" F BSPT
PMR20MF1.38 bar6.89 bar454 - 4543 L/hr3/4" F NPT, 1" F NPT, 1" F BSPT3/4" F NPT, 1" F NPT, 1" F BSPT
PMR25MF1.72 bar7.24 bar454 - 4543 L/hr3/4" F NPT, 1" F NPT, 1" F BSPT3/4" F NPT, 1" F NPT, 1" F BSPT
PMR30MF2.07 bar7.58 bar454 - 4543 L/hr3/4" F NPT, 1" F NPT, 1" F BSPT3/4" F NPT, 1" F NPT, 1" F BSPT
PMR35MF2.41 bar7.93 bar454 - 4543 L/hr3/4" F NPT, 1" F NPT, 1" F BSPT3/4" F NPT, 1" F NPT, 1" F BSPT
PMR40MF2.76 bar8.27 bar454 - 4543 L/hr3/4" F NPT, 1" F NPT, 1" F BSPT3/4" F NPT, 1" F NPT, 1" F BSPT
PMR50MF3.45 bar8.96 bar454 - 4543 L/hr3/4" F NPT, 1" F NPT, 1" F BSPT3/4" F NPT, 1" F NPT, 1" F BSPT
PMR60MF4.14 bar9.65 bar454 - 4543 L/hr3/4" F NPT, 1" F NPT, 1" F BSPT3/4" F NPT, 1" F NPT, 1" F BSPT

The pressure regulator shall maintain the predetermined operating pressure provided that the inlet pressure is at least 5 psi (0.34 bar) above the expected outlet pressure, but not exceeding the maximum inlet pressure as shown above.

Recommended for outdoor use only. Not NSF certified.

PR-HF (Metric)

PR-HF
MODELS
Preset 
Outlet Pressure
Maximum Inlet PressureFlow RangeInlet SizesOutlet Sizes
PR10HF0.69 bar6.20 bar2271 - 7268 L/hr1¼" F NPT,
1¼" F BSPT
1" F NPT, 1¼" F NPT,
1" F BSPT, 1¼" F BSPT
PR15HF1.03 bar6.55 bar2271 - 7268 L/hr1¼" F NPT,
1¼" F BSPT
1" F NPT, 1¼" F NPT,
1" F BSPT, 1¼" F BSPT
PR20HF1.38 bar6.89 bar2271 - 7268 L/hr1¼" F NPT,
1¼" F BSPT
1" F NPT, 1¼" F NPT,
1" F BSPT, 1¼" F BSPT
PR25HF1.72 bar7.24 bar2271 - 7268 L/hr1¼" F NPT,
1¼" F BSPT
1" F NPT, 1¼" F NPT,
1" F BSPT, 1¼" F BSPT
PR30HF2.07 bar7.58 bar2271 - 7268 L/hr1¼" F NPT,
1¼" F BSPT
1" F NPT, 1¼" F NPT,
1" F BSPT, 1¼" F BSPT
PR40HF2.76 bar8.27 bar2271 - 7268 L/hr1¼" F NPT,
1¼" F BSPT
1" F NPT, 1¼" F NPT,
1" F BSPT, 1¼" F BSPT
PR50HF3.45 bar8.96 bar2271 - 7268 L/hr1¼" F NPT,
1¼" F BSPT
1" F NPT, 1¼" F NPT,
1" F BSPT, 1¼" F BSPT

The pressure regulator shall maintain the predetermined operating pressure provided that the inlet pressure is at least 5 psi (0.34 bar) above the expected outlet pressure, but not exceeding the maximum inlet pressure as shown above.

Recommended for outdoor use only. Not NSF certified.

PRU (Metric)

PRU
MODELS
Preset Outlet PressureMaximum Inlet PressureFlow RangeInlet SizesOutlet Sizes
PRU100.69 bar6.20 bar4543 - 22713 L/hr2" F NPT, 2" F BSPT2" F NPT, 2" F BSPT
PRU151.03 bar6.55 bar4543 - 22713 L/hr2" F NPT, 2" F BSPT2" F NPT, 2" F BSPT
PRU201.38 bar6.89 bar4543 - 22713 L/hr2" F NPT, 2" F BSPT2" F NPT, 2" F BSPT
PRU251.72 bar7.24 bar4543 - 22713 L/hr2" F NPT, 2" F BSPT2" F NPT, 2" F BSPT
PRU302.07 bar7.58 bar4543 - 22713 L/hr2" F NPT, 2" F BSPT2" F NPT, 2" F BSPT
PRU402.76 bar8.27 bar4543 - 22713 L/hr2" F NPT, 2" F BSPT2" F NPT, 2" F BSPT
PRU503.45 bar8.96 bar4543 - 22713 L/hr2" F NPT, 2" F BSPT2" F NPT, 2" F BSPT
PRU604.14 bar9.65 bar4543 - 22713 L/hr2" F NPT, 2" F BSPT2" F NPT, 2" F BSPT

The pressure regulator shall maintain the predetermined operating pressure provided that the inlet pressure is at least 5 psi (0.34 bar) above the expected outlet pressure, but not exceeding the maximum inlet pressure as shown above.

Recommended for outdoor use only. Not NSF certified.

PRU-LV (Metric)

PRU-LV
MODELS
Preset Outlet PressureMaximum Inlet PressureFlow RangeInlet SizesOutlet Sizes
PRU LV 100.69 bar8.62 barup to 22713 L/hr2" F NPT, 2" F BSPT2" F NPT, 2" F BSPT
PRU LV 151.03 bar8.62 barup to 22713 L/hr2" F NPT, 2" F BSPT2" F NPT, 2" F BSPT
PRU LV 201.38 bar8.62 barup to 22713 L/hr2" F NPT, 2" F BSPT2" F NPT, 2" F BSPT
PRU LV 251.72 bar8.62 barup to 22713 L/hr2" F NPT, 2" F BSPT2" F NPT, 2" F BSPT
PRU LV 302.07 bar8.62 barup to 22713 L/hr2" F NPT, 2" F BSPT2" F NPT, 2" F BSPT
PRU LV 402.76 bar8.62 barup to 22713 L/hr2" F NPT, 2" F BSPT2" F NPT, 2" F BSPT
PRU LV 503.45 bar8.62 barup to 22713 L/hr2" F NPT, 2" F BSPT2" F NPT, 2" F BSPT
PRU LV 604.14 bar8.62 barup to 22713 L/hr2" F NPT, 2" F BSPT2" F NPT, 2" F BSPT

The PRU-LV limits downstream pressure to no more than 1.03 bar above regulated pressure during static (no flow) conditions.

Recommended for outdoor use only. Not NSF certified.

PRLV (Metric)

PRLV
MODELS
Preset Outlet PressureMaximum Inlet PressureMaximum FlowInlet SizesOutlet Sizes
PRLV100.69 bar8.62 bar4088 L/hr3/4" F NPT, 1" F NPT3/4" F NPT, 1" F NPT
PRLV151.03 bar8.62 bar4088 L/hr3/4" F NPT, 1" F NPT3/4" F NPT, 1" F NPT
PRLV201.38 bar8.62 bar4088 L/hr3/4" F NPT, 1" F NPT3/4" F NPT, 1" F NPT
PRLV302.07 bar8.62 bar4088 L/hr3/4" F NPT, 1" F NPT3/4" F NPT, 1" F NPT
PRLV402.76 bar8.62 bar4088 L/hr3/4" F NPT, 1" F NPT3/4" F NPT, 1" F NPT
PRLV503.45 bar8.62 bar4088 L/hr3/4" F NPT, 1" F NPT3/4" F NPT, 1" F NPT
PRLV604.14 bar8.62 bar4088 L/hr3/4" F NPT, 1" F NPT3/4" F NPT, 1" F NPT

The PRLV limits downstream pressure to no more than 15 psi (1.03 bar) above regulated pressure during static (no flow) conditions.

Recommended for outdoor use only. Not NSF certified.