ICV
- Reliable: Can consistently withstand pressure of up to 15 bar
- Durable: Built with glass-filled nylon that results in extremely sturdy construction
- Flow Control: Allows for the fine-tuning of flow and pressure for each zone
Filter
Pop-up Height
Arc Option
Radius
Nozzle Type
Flow Rate
Inlet Size
Inlet Type
Outlet Type
Outlet Style
Lay Length
Nozzle Option
Emitter Spacing
Coil Length
| Model | Description | Add to List |
|---|---|---|
| ICV-101G | ICV Valve, 1" (25 mm) glass-filled nylon globe valve with flow control | + |
| ICV-101G-FS | ICV Valve, 1" (25 mm) glass-filled nylon globe valve with flow control and factory-installed Filter Sentry Mechanism | + |
| ICV-101G-DC | ICV Valve, 1" (25 mm) glass-filled nylon globe valve with flow control and DC-Latching Solenoid | + |
| ICV-101G-FS-R | ICV Valve, 1" (25 mm) glass-filled nylon globe valve with flow control, factory-installed Filter Sentry Mechanism, and reclaimed ID knob and tag | + |
| ICV-101G-FS-DC | ICV Valve, 1" (25 mm) glass-filled nylon globe valve with flow control, factory-installed Filter Sentry Mechanism, and DC-Latching Solenoid | + |
| ICV-151G | ICV Valve, 1½" (40 mm) glass-filled nylon globe valve with flow control | + |
| ICV-151G-FS | ICV Valve, 1½" (40 mm) glass-filled nylon globe valve with flow control and factory-installed Filter Sentry Mechanism | + |
| ICV-151G-DC | ICV Valve, 1½" (40 mm) glass-filled nylon globe valve with flow control and DC-Latching Solenoid | + |
| ICV-151G-FS-R | ICV Valve, 1½" (40 mm) glass-filled nylon globe valve with flow control, purple diaphragm with factory-installed Filter Sentry Mechanism, and reclaimed ID knob and tag | + |
| ICV-151G-FS-DC | ICV Valve, 1½" (40 mm) glass-filled nylon globe valve with flow control, factory-installed Filter Sentry Mechanism, and DC-Latching Solenoid | + |
| ICV-201G | ICV Valve, 2" (50 mm) glass-filled nylon globe valve with flow control | + |
| ICV-201G-FS | ICV Valve, 2" (50 mm) glass-filled nylon globe valve with flow control and factory-installed Filter Sentry Mechanism | + |
| ICV-201G-FS-R | ICV Valve, 2" (50 mm) glass-filled nylon globe valve with flow control, purple diaphragm with factory-installed Filter Sentry Mechanism, and reclaimed ID knob and tag | + |
| ICV-201G-DC | ICV Valve, 2" (50 mm) glass-filled nylon globe valve with flow control and DC-Latching Solenoid | + |
| ICV-201G-FS-DC | ICV Valve, 2" (50 mm) glass-filled nylon globe valve with flow control, factory-installed Filter Sentry Mechanism, and DC-Latching Solenoid | + |
| ICV-301 | ICV Valve, 80 mm glass-filled nylon globe / angle valve with flow control | + |
| ICV-301-FS | ICV Valve, 80 mm glass-filled nylon globe / angle valve with flow control and factory-installed Filter Sentry Mechanism | + |
| ICV-301-DC | ICV Valve, 80 mm glass-filled nylon globe / angle valve with flow control and DC-Latching Solenoid | + |
Create a new My List.
Contact your local distributor for product availability and ordering.
Specifications
User-Installed Options
- Accu Sync™ pressure regulation at the valve*
- DC-latching solenoid for battery-powered controllers (P/N 458200)
- Filter Sentry easily added to an installed valve
- Solenoid conduit cover (P/N 464322)
Factory-Installed Options
- LS: Valve without solenoid
- DC: DC-latching solenoid for battery-powered controllers
- FS: Filter Sentry
- FS-R: Reclaimed option with Filter Sentry, purple control knob, and purple chlorine-resistant diaphragm
Operating Specifications
- Flow:
- ICV-101G: 0.03 to 9 m3 /hr; 0.4 to 150 l/min
- ICV-151G: 0.03 to 34 m3 /hr; 0.4 to 568 l/min
- ICV-201G: 0.03 to 45 m3 /hr; 0.4 to 757 l/min
- ICV-301: 0.03 to 68 m3 /hr; 0.4 to 1,135 l/min
- Recommended pressure range: 1.5 to 15.0 bar; 150 to 1500 kPa
- Temperature rating: 66°C
- Warranty period: 5 years
Solenoid Specifications
- 24 VAC solenoid
- 350 mA inrush, 190 mA holding, 60 Hz
- 370 mA inrush, 210 mA holding, 50 Hz
Animation: Valve Diaphragm Operation
Videos
Pagination
Features
In order to create a plastic valve that can consistently operate at 15 bar, Hunter relies on only materials that are both time and contractor proven. Created to handle the wide range of conditions different sites will bring, the ICV valve includes both a fabric reinforced EPDM diaphragm and seat, and flow control as standard features. It can consistently withstand pressures of up to 15 bar while handling the continual hammer that such forces will produce. Plus, it’s exceptionally easy to service, with bonnet bolts that can be loosened and tightened using a variety of common contractor tools. A Filter Sentry™ option is also available for applications that involve dirty water. The Filter Sentry™ system keeps the the valve filter screen free of debris commonly found in non-potable water sources.
Key Benefits
Advanced Features
Maximise efficiency and prolong the life of a system by fine-tuning flow and pressure for each zone. Learn more about flow control.
The Filter Sentry Mechanism scours the filter clean with a wiper that slides up, covers the entire screen when the valve opens, then continues to scrub the filter's upper part during valve operation. It can be added after the valve is installed as well.
Avoid over-pressurisation from sprinklers and achieve significant water savings with Hunter's adjustable Accu Sync Pressure Regulator.
A double-beaded, chlorine-resistant purple diaphragm assembly delivers the ultimate defense against high levels of chlorine and chloramines in reclaimed water applications. Purple tags and handles provide clear, quick, and simple identification of non-potable water use.
Valve Models
ICV-100, ICV-151, ICV-201
- Reclaimed Water Handle (P/N 561205)
ICV-301
- Reclaimed Water Handle (P/N 515005)
Charts
| ICV Pressure Loss in Bar | |||||
|---|---|---|---|---|---|
| Flow | 1" (25 mm) | 1½" (40 mm) | 2" (50 mm) | 3" (80 mm) | |
| m³/hr | Globe | Globe | Globe | Globe | Angle |
| 0.05 | 0.1 | ||||
| 0.1 | 0.1 | ||||
| 0.3 | 0.1 | ||||
| 1.0 | 0.2 | ||||
| 2.5 | 0.2 | ||||
| 3.5 | 0.2 | ||||
| 4.5 | 0.2 | 0.1 | |||
| 7.0 | 0.4 | 0.1 | |||
| 9.0 | 1.0 | 0.1 | 0.1 | ||
| 11.0 | 0.2 | 0.1 | |||
| 13.5 | 0.2 | 0.1 | |||
| 17.0 | 0.3 | 0.1 | |||
| 20.5 | 0.4 | 0.2 | |||
| 23.0 | 0.5 | 0.3 | |||
| 27.0 | 0.7 | 0.4 | |||
| 30.5 | 0.9 | 0.5 | |||
| 34.0 | 1.2 | 0.6 | 0.2 | 0.1 | |
| 40.0 | 0.9 | 0.2 | 0.2 | ||
| 45.5 | 1.2 | 0.3 | 0.2 | ||
| 51.0 | 0.3 | 0.3 | |||
| 57.0 | 0.4 | 0.4 | |||
| 62.5 | 0.5 | 0.5 | |||
| 68.0 | 0.6 | 0.6 | |||
| ICV Pressure Loss in KPA | |||||
|---|---|---|---|---|---|
| Flow | 1" (25 mm) | 1½" (40 mm) | 2" (50 mm) | 3" (80 mm) | |
| l/min | Globe | Globe | Globe | Globe | Angle |
| 1 | 14 | ||||
| 2 | 14 | ||||
| 4 | 14 | ||||
| 20 | 17 | ||||
| 40 | 20 | ||||
| 60 | 20 | ||||
| 75 | 20 | 9.6 | |||
| 115 | 62 | 10 | |||
| 150 | 139 | 12 | 5 | ||
| 190 | 15 | 7 | |||
| 225 | 18 | 9.3 | |||
| 280 | 26 | 14 | |||
| 340 | 37 | 20 | |||
| 380 | 46 | 26 | |||
| 450 | 65 | 36 | |||
| 510 | 84 | 47 | |||
| 565 | 104 | 57 | 16 | 12 | |
| 660 | 79 | 22 | 17 | ||
| 750 | 103 | 29 | 23 | ||
| 850 | 38 | 30 | |||
| 950 | 47 | 38 | |||
| 1050 | 58 | 47 | |||
| 1135 | 69 | 56 | |||
Documents
Select Type
- All Documents
- Manuals
- Marketing
- Specifications
- Replacement Parts
| ICV-101G | DWG | DXF | ||
| ICV-101G With Accu Sync | DWG | |||
| ICV-101G with shutoff valve | DWG | DXF | ||
| ICV-101G with unions | DWG | DXF | ||
| ICV-101G with unions and shutoff valve | DWG | DXF | ||
| ICV-151G | DWG | DXF | ||
| ICV-151G With Accu Sync | DWG | |||
| ICV-151G with shutoff valve | DWG | DXF | ||
| ICV-151G with unions | DWG | DXF | ||
| ICV-151G with unions and shutoff valve | DWG | DXF | ||
| ICV-201G | DWG | DXF | ||
| ICV-201G With Accu Sync | DWG | |||
| ICV-201G with unions | DWG | DXF | ||
| ICV-201G with unions and shutoff valve | DWG | DXF | ||
| ICV-301A | DWG | DXF | ||
| ICV-301A With Accu Sync | DWG | |||
| ICV-301A with unions | DWG | DXF | ||
| ICV-301G | DWG | DXF | ||
| ICV-301G With Accu Sync | DWG | |||
| ICV-301G with shutoff valve | DWG | DXF |
Pagination
Pagination
Support
Photos
Application Photos
Download Image
Medium Original
Download Image
Medium Original
Download Image
Medium Original
Download Image
Medium OriginalStudio Photos
Download Image
Medium Original
Download Image
Medium Original
Download Image
Medium Original
Download Image
Medium Original
Download Image
Medium Original
Download Image
Medium Original
Download Image
Medium Original
Download Image
Medium Original