PR-HF
MODELS
Preset 
Outlet Pressure
Maximum Inlet PressureFlow RangeInlet SizesOutlet Sizes
PR10HF0.69 bar6.20 bar2271 - 7268 L/hr1¼" F NPT,
1¼" F BSPT
1" F NPT, 1¼" F NPT,
1" F BSPT, 1¼" F BSPT
PR15HF1.03 bar6.55 bar2271 - 7268 L/hr1¼" F NPT,
1¼" F BSPT
1" F NPT, 1¼" F NPT,
1" F BSPT, 1¼" F BSPT
PR20HF1.38 bar6.89 bar2271 - 7268 L/hr1¼" F NPT,
1¼" F BSPT
1" F NPT, 1¼" F NPT,
1" F BSPT, 1¼" F BSPT
PR25HF1.72 bar7.24 bar2271 - 7268 L/hr1¼" F NPT,
1¼" F BSPT
1" F NPT, 1¼" F NPT,
1" F BSPT, 1¼" F BSPT
PR30HF2.07 bar7.58 bar2271 - 7268 L/hr1¼" F NPT,
1¼" F BSPT
1" F NPT, 1¼" F NPT,
1" F BSPT, 1¼" F BSPT
PR40HF2.76 bar8.27 bar2271 - 7268 L/hr1¼" F NPT,
1¼" F BSPT
1" F NPT, 1¼" F NPT,
1" F BSPT, 1¼" F BSPT
PR50HF3.45 bar8.96 bar2271 - 7268 L/hr1¼" F NPT,
1¼" F BSPT
1" F NPT, 1¼" F NPT,
1" F BSPT, 1¼" F BSPT

The pressure regulator shall maintain the predetermined operating pressure provided that the inlet pressure is at least 5 psi (0.34 bar) above the expected outlet pressure, but not exceeding the maximum inlet pressure as shown above.

Recommended for outdoor use only. Not NSF certified.