Create a new My List.
PR-HF
More information about Senninger® Pressure Regulators
Product Information
Operating Specifications
Additional Information
| PR-HF Models | |
|---|---|
| Part Number | Description |
| 1-1/4" x 1" NPT models | |
| PR10HF5F4FV | 10 psi, inlet 1-1/4" F NPT, outlet 1" F NPT |
| PR15HF5F4FV | 15 psi, inlet 1-1/4" F NPT, outlet 1" F NPT |
| PR20HF5F4FV | 20 psi, inlet 1-1/4" F NPT, outlet 1" F NPT |
| PR25HF5F4FV | 25 psi, inlet 1-1/4" F NPT, outlet 1" F NPT |
| PR30HF5F4FV | 30 psi, inlet 1-1/4" F NPT, outlet 1" F NPT |
| PR40HF5F4FV | 40 psi, inlet 1-1/4" F NPT, outlet 1" F NPT |
| PR50HF5F4FV | 50 psi, inlet 1-1/4" F NPT, outlet 1" F NPT |
| 1-1/4" x 1-1/4" NPT models | |
| PR10HF5F5FV | 10 psi, inlet 1-1/4" F NPT, outlet 1-1/4" F NPT |
| PR15HF5F5FV | 15 psi, inlet 1-1/4" F NPT, outlet 1-1/4" F NPT |
| PR20HF5F5FV | 20 psi, inlet 1-1/4" F NPT, outlet 1-1/4" F NPT |
| PR25HF5F5FV | 25 psi, inlet 1-1/4" F NPT, outlet 1-1/4" F NPT |
| PR30HF5F5FV | 30 psi, inlet 1-1/4" F NPT, outlet 1-1/4" F NPT |
| PR40HF5F5FV | 40 psi, inlet 1-1/4" F NPT, outlet 1-1/4" F NPT |
| PR50HF5F5FV | 50 psi, inlet 1-1/4" F NPT, outlet 1-1/4" F NPT |
| 1-1/4" x 1-1/4" BSPT models | |
| PR10HF5FB5FBV | 10 psi, inlet 1-1/4" F BSPT, outlet 1-1/4" F BSPT |
| PR15HF5FB5FBV | 15 psi, inlet 1-1/4" F BSPT, outlet 1-1/4" F BSPT |
| PR20HF5FB5FBV | 20 psi, inlet 1-1/4" F BSPT, outlet 1-1/4" F BSPT |
| PR25HF5FB5FBV | 25 psi, inlet 1-1/4" F BSPT, outlet 1-1/4" F BSPT |
| PR30HF5FB5FBV | 30 psi, inlet 1-1/4" F BSPT, outlet 1-1/4" F BSPT |
| PR40HF5FB5FBV | 40 psi, inlet 1-1/4" F BSPT, outlet 1-1/4" F BSPT |
| PR50HF5FB5FBV | 50 psi, inlet 1-1/4" F BSPT, outlet 1-1/4" F BSPT |
| 1-1/4" x 1" BSPT models | |
| PR10HF5FB4FBV | 10 psi, inlet 1-1/4" F BSPT, outlet 1" F BSPT |
| PR15HF5FB4FBV | 15 psi, inlet 1-1/4" F BSPT, outlet 1" F BSPT |
| PR20HF5FB4FBV | 20 psi, inlet 1-1/4" F BSPT, outlet 1" F BSPT |
| PR25HF5FB4FBV | 25 psi, inlet 1-1/4" F BSPT, outlet 1" F BSPT |
| PR30HF5FB4FBV | 30 psi, inlet 1-1/4" F BSPT, outlet 1" F BSPT |
| PR40HF5FB4FBV | 40 psi, inlet 1-1/4" F BSPT, outlet 1" F BSPT |
| PR50HF5FB4FBV | 50 psi, inlet 1-1/4" F BSPT, outlet 1" F BSPT |
Specification Charts
Pressure Regulators Comparison (Metric)
* Varies by model, check models chart.
MPR
| MPR MODELS | Preset Operating Pressure | Maximum Inlet Pressure | Flow Range | Inlet Sizes | Outlet Sizes |
| MPR152M2F | 15 psi | 45 psi | 0.5 - 2.3 gpm | 1/2" M NPT | 1/2" F NPT |
| MPR202M2F | 20 psi | 50 psi | 0.5 - 2.5 gpm | 1/2" M NPT | 1/2" F NPT |
| MPR302M2F | 30 psi | 60 psi | 0.6 - 3.1 gpm | 1/2" M NPT | 1/2" F NPT |
| MPR402M2F | 40 psi | 80 psi | 0.7 - 3.5 gpm | 1/2" M NPT | 1/2" F NPT |
The pressure regulator shall maintain the predetermined operating pressure provided that the inlet pressure is at least 5 psi above the expected outlet pressure, but not exceeding the maximum inlet pressure as shown above.
Recommended for outdoor use only. Not NSF certified.
PRLG
| PRLG MODELS | Preset Outlet Pressure | Maximum Inlet Pressure | Flow Range | Inlet Sizes | Outlet Sizes |
| PRLG10TLBTLB | 10 psi | 25 psi | 0.5 - 7 gpm | tape barb (5/8") with lock nuts (green) | tape barb (5/8") with lock nuts (green) |
| PRLG15TLBTLB | 15 psi | 25 psi | 0.5 - 7 gpm | tape barb (5/8") with lock nuts (green) | tape barb (5/8") with lock nuts (green) |
| PRLG105LB5LB | 10 psi | 50 psi | 0.5 - 7 gpm | 500 barb (16 mm) with lock nuts (black) | 500 barb (16 mm) with lock nuts (black) |
| PRLG155LB5LB | 15 psi | 50 psi | 0.5 - 7 gpm | 500 barb (16 mm) with lock nuts (black) | 500 barb (16 mm) with lock nuts (black) |
| PRLG205LB5LB | 20 psi | 50 psi | 0.5 - 7 gpm | 500 barb (16 mm) with lock nuts (black) | 500 barb (16 mm) with lock nuts (black) |
| PRLG106LB6LB | 10 psi | 50 psi | 0.5 - 7 gpm | 600 barb (18 mm) with lock nuts (black) | 600 barb (18 mm) with lock nuts (black) |
| PRLG156LB6LB | 15 psi | 50 psi | 0.5 - 7 gpm | 600 barb (18 mm) with lock nuts (black) | 600 barb (18 mm) with lock nuts (black) |
| PRLG206LB6LB | 20 psi | 50 psi | 0.5 - 7 gpm | 600 barb (18 mm) with lock nuts (black) | 600 barb (18 mm) with lock nuts (black) |
| PRLG103FH3MH | 10 psi | 90 psi | 0.5 - 7 gpm | ¾" F hose | ¾" M hose |
| PRLG153FH3MH | 15 psi | 95 psi | 0.5 - 7 gpm | ¾" F hose | ¾" M hose |
| PRLG203FH3MH | 20 psi | 100 psi | 0.5 - 7 gpm | ¾" F hose | ¾" M hose |
| PRLG253FH3MH | 25 psi | 105 psi | 0.5 - 7 gpm | ¾" F hose | ¾" M hose |
| PRLG303FH3MH | 30 psi | 110 psi | 0.5 - 7 gpm | ¾" F hose | ¾" M hose |
| PRLG353FH3MH | 35 psi | 115 psi | 0.5 - 7 gpm | ¾" F hose | ¾" M hose |
| PRLG403FH3MH | 40 psi | 120 psi | 0.5 - 7 gpm | ¾" F hose | ¾" M hose |
| PRLG103F3M | 10 psi | 90 psi | 0.5 - 7 gpm | ¾" F NPT | ¾" M NPT |
| PRLG153F3M | 15 psi | 95 psi | 0.5 - 7 gpm | ¾" F NPT | ¾" M NPT |
| PRLG203F3M | 20 psi | 100 psi | 0.5 - 7 gpm | ¾" F NPT | ¾" M NPT |
| PRLG253F3M | 25 psi | 105 psi | 0.5 - 7 gpm | ¾" F NPT | ¾" M NPT |
| PRLG303F3M | 30 psi | 110 psi | 0.5 - 7 gpm | ¾" F NPT | ¾" M NPT |
| PRLG353F3M | 35 psi | 115 psi | 0.5 - 7 gpm | ¾" F NPT | ¾" M NPT |
| PRLG403F3M | 40 psi | 120 psi | 0.5 - 7 gpm | ¾" F NPT | ¾" M NPT |
The pressure regulator shall maintain the predetermined operating pressure provided that the inlet pressure is at least 5 psi above the expected outlet pressure, but not exceeding the maximum inlet pressure as shown above.
Recommended for outdoor use only. Not NSF certified.
PRMP
| PRMP MODELS | Preset Outlet Pressure | Maximum Inlet Pressure | Flow Range | Inlet Sizes | Outlet Sizes |
| PRMP153FH3MH | 15 psi | 95 psi | 0.5 - 7 gpm | 3/4" F Hose | 3/4" M Hose |
| PRMP203FH3MH | 20 psi | 100 psi | 0.5 - 7 gpm | 3/4" F Hose | 3/4" M Hose |
| PRMP253FH3MH | 25 psi | 105 psi | 0.5 - 7 gpm | 3/4" F Hose | 3/4" M Hose |
| PRMP303FH3MH | 30 psi | 110 psi | 0.5 - 7 gpm | 3/4" F Hose | 3/4" M Hose |
| PRMP353FH3MH | 35 psi | 115 psi | 0.5 - 7 gpm | 3/4" F Hose | 3/4" M Hose |
| PRMP403FH3MH | 40 psi | 120 psi | 0.5 - 7 gpm | 3/4" F Hose | 3/4" M Hose |
| PRMP103F3M | 10 psi | 90 psi | 0.5 - 7 gpm | 3/4" F NPT | 3/4" M NPT |
| PRMP153F3M | 15 psi | 95 psi | 0.5 - 7 gpm | 3/4" F NPT | 3/4" M NPT |
| PRMP203F3M | 20 psi | 100 psi | 0.5 - 7 gpm | 3/4" F NPT | 3/4" M NPT |
| PRMP253F3M | 25 psi | 105 psi | 0.5 - 7 gpm | 3/4" F NPT | 3/4" M NPT |
| PRMP303F3M | 30 psi | 110 psi | 0.5 - 7 gpm | 3/4" F NPT | 3/4" M NPT |
| PRMP353F3M | 35 psi | 115 psi | 0.5 - 7 gpm | 3/4" F NPT | 3/4" M NPT |
| PRMP403F3M | 40 psi | 120 psi | 0.5 - 7 gpm | 3/4" F NPT | 3/4" M NPT |
| PRMP10TLBTLB | 10 psi | 25 psi | 0.5 - 7 gpm | tape (5/8") | tape (5/8") |
| PRMP15TLBTLB | 15 psi | 25 psi | 0.5 - 7 gpm | tape (5/8") | tape (5/8") |
| PRMP155LB5LB | 10 psi | 50 psi | 0.5 - 7 gpm | 500 (16 mm) | 500 (16 mm) |
| PRMP155LB5LB | 15 psi | 50 psi | 0.5 - 7 gpm | 500 (16 mm) | 500 (16 mm) |
| PRMP205LB5LB | 20 psi | 50 psi | 0.5 - 7 gpm | 500 (16 mm) | 500 (16 mm) |
| PRMP156LB6LB | 10 psi | 50 psi | 0.5 - 7 gpm | 600 (18 mm) | 600 (18 mm) |
| PRMP156LB6LB | 15 psi | 50 psi | 0.5 - 7 gpm | 600 (18 mm) | 600 (18 mm) |
| PRMP206LB6LB | 20 psi | 50 psi | 0.5 - 7 gpm | 600 (18 mm) | 600 (18 mm) |
The pressure regulator shall maintain the predetermined operating pressure provided that the inlet pressure is at least 5 psi above the expected outlet pressure, but not exceeding the maximum inlet pressure as shown above.
PRL
| PRL MODELS | Preset Outlet Pressure | Maximum Inlet Pressure | Flow Range | Inlet Sizes | Outlet Sizes |
| PRL06 | 6 psi | 80 psi | 0.5 - 5 gpm | 3/4" F NPT, 3/4" F hose | 3/4" F NPT |
| PRL10 | 10 psi | 90 psi | 0.5 - 8 gpm | 3/4" F NPT, 3/4" F hose | 3/4" F NPT |
| PRL12 | 12 psi | 90 psi | 0.5 - 8 gpm | 3/4" F NPT, 3/4" F hose | 3/4" F NPT |
| PRL15 | 15 psi | 95 psi | 0.5 - 8 gpm | 3/4" F NPT, 3/4" F hose | 3/4" F NPT |
| PRL20 | 20 psi | 100 psi | 0.5 - 8 gpm | 3/4" F NPT, 3/4" F hose | 3/4" F NPT |
| PRL25 | 25 psi | 105 psi | 0.5 - 8 gpm | 3/4" F NPT, 3/4" F hose | 3/4" F NPT |
| PRL30 | 30 psi | 110 psi | 0.5 - 8 gpm | 3/4" F NPT, 3/4" F hose | 3/4" F NPT |
| PRL35 | 35 psi | 115 psi | 0.5 - 8 gpm | 3/4" F NPT, 3/4" F hose | 3/4" F NPT |
| PRL40 | 40 psi | 120 psi | 0.5 - 8 gpm | 3/4" F NPT, 3/4" F hose | 3/4" F NPT |
The pressure regulator shall maintain the predetermined operating pressure provided that the inlet pressure is at least 5 psi above the expected outlet pressure, but not exceeding the maximum inlet pressure as shown above.
Recommended for outdoor use only. Not NSF certified.
PSR™2
| PSR-2 MODELS | Preset Outlet Pressure | Maximum Inlet Pressure | Flow Range | Inlet Sizes | Outlet Sizes |
| PSR-2-06 | 6 psi | 80 psi | 0.5 - 15 gpm | 3/4" F NPT | 3/4" F NPT |
| PSR-2-10 | 10 psi | 90 psi | 0.5 - 15 gpm | 3/4" F NPT | 3/4" F NPT |
| PSR-2-12 | 12 psi | 90 psi | 0.5 - 15 gpm | 3/4" F NPT | 3/4" F NPT |
| PSR-2-15 | 15 psi | 95 psi | 0.5 - 15 gpm | 3/4" F NPT | 3/4" F NPT |
| PSR-2-20 | 20 psi | 100 psi | 0.5 - 15 gpm | 3/4" F NPT | 3/4" F NPT |
| PSR-2-25 | 25 psi | 105 psi | 0.5 - 15 gpm | 3/4" F NPT | 3/4" F NPT |
| PSR-2-30 | 30 psi | 110 psi | 0.5 - 15 gpm | 3/4" F NPT | 3/4" F NPT |
| PSR-2-35 | 35 psi | 115 psi | 0.5 - 15 gpm | 3/4" F NPT | 3/4" F NPT |
| PSR-2-40 | 40 psi | 120 psi | 0.5 - 15 gpm | 3/4" F NPT | 3/4" F NPT |
| PSR-2-50 | 50 psi | 130 psi | 0.5 - 15 gpm | 3/4" F NPT | 3/4" F NPT |
The pressure regulator shall maintain the predetermined operating pressure provided that the inlet pressure is at least 5 psi above the expected outlet pressure, but not exceeding the maximum inlet pressure as shown above.
Recommended for outdoor use only. Not NSF certified.
Filter Regulator
| Filter Regulator MODELS | Preset Outlet Pressure | Maximum Inlet Pressure | Mesh Filter Screen | Mesh Orifice (microns) | UP3 Nozzle Number |
| FPSR2063M3F20 | 6 psi | 80 psi | 20 mesh (black rings) | 841 | #13 - #26 |
| FPSR2063M3F30 | 30 mesh (green rings) | 595 | #6 - #12.5 | ||
| FPSR2063M3F40 | 40 mesh (grey rings) | 400 | #2 - #5.5 | ||
| FPSR2103M3F20 | 10 psi | 90 psi | 20 mesh (black rings) | 841 | #13 - #26 |
| FPSR2103M3F30 | 30 mesh (green rings) | 595 | #6 - #12.5 | ||
| FPSR2103M3F40 | 40 mesh (grey rings) | 400 | #2 - #5.5 | ||
| FPSR2153M3F20 | 15 psi | 95 psi | 20 mesh (black rings) | 841 | #13 - #26 |
| FPSR2153M3F30 | 30 mesh (green rings) | 595 | #6 - #12.5 | ||
| FPSR2153M3F40 | 40 mesh (grey rings) | 400 | #2 - #5.5 | ||
| FPSR2203M3F20 | 20 psi | 100 psi | 20 mesh (black rings) | 841 | #13 - #26 |
| FPSR2203M3F30 | 30 mesh (green rings) | 595 | #6 - #12.5 | ||
| FPSR2203M3F40 | 40 mesh (grey rings) | 400 | #2 - #5.5 | ||
| FPSR2103M3F120 | 10 psi | 90 psi | 120 mesh screen (red rings) | 125 | 0.5 - 15 gpm |
| FPSR2103M3F140 | 140 mesh screen (blue rings) | 105 | |||
| FPSR2153M3F120 | 15 psi | 95 psi | 120 mesh screen (red rings) | 125 | 0.5 - 15 gpm |
| FPSR2153M3F140 | 140 mesh screen (blue rings) | 105 | |||
| FPSR2203M3F120 | 20 psi | 100 psi | 120 mesh screen (red rings) | 125 | 0.5 - 15 gpm |
| FPSR2203M3F140 | 140 mesh screen (blue rings) | 105 | |||
Shaded models designed for use with drip systems.
The pressure regulator shall maintain the predetermined operating pressure provided that the inlet pressure is at least 5 psi (0.34 bar) above the expected outlet pressure, with flows up to 11 gpm (2498 L/hr), but not exceeding the maximum inlet pressure of 80 psi above the model’s pressure rating. Higher flows require additional inlet pressure to engage the regulator. Where flows are greater than 11 gpm (2498 L/hr), the inlet pressure should be at least 9 psi (0.62 bar) above the expected outlet pressure but not exceeding the maximum inlet pressure of 80 psi above the model’s pressure rating.
Pressure regulators should always be installed downstream of all shut-off valves.
Recommended for outdoor use only. Not NSF certified.
PMR-MF
| PMR-MF MODELS | Preset OUTLET Pressure | Maximum Inlet Pressure | Flow Range | Inlet Sizes | Outlet Sizes |
| PMR06MF | 6 psi | 80 psi | 4 - 16 gpm | 3/4" F NPT, 1" F NPT, 1" F BSPT | 3/4" F NPT, 1" F NPT, 1" F BSPT |
| PMR10MF | 10 psi | 90 psi | 4 - 16 gpm | 3/4" F NPT, 1" F NPT, 1" F BSPT | 3/4" F NPT, 1" F NPT, 1" F BSPT |
| PMR12MF | 12 psi | 90 psi | 2 - 20 gpm | 3/4" F NPT, 1" F NPT, 1" F BSPT | 3/4" F NPT, 1" F NPT, 1" F BSPT |
| PMR15MF | 15 psi | 95 psi | 2 - 20 gpm | 3/4" F NPT, 1" F NPT, 1" F BSPT | 3/4" F NPT, 1" F NPT, 1" F BSPT |
| PMR20MF | 20 psi | 100 psi | 2 - 20 gpm | 3/4" F NPT, 1" F NPT, 1" F BSPT | 3/4" F NPT, 1" F NPT, 1" F BSPT |
| PMR25MF | 25 psi | 105 psi | 2 - 20 gpm | 3/4" F NPT, 1" F NPT, 1" F BSPT | 3/4" F NPT, 1" F NPT, 1" F BSPT |
| PMR30MF | 30 psi | 110 psi | 2 - 20 gpm | 3/4" F NPT, 1" F NPT, 1" F BSPT | 3/4" F NPT, 1" F NPT, 1" F BSPT |
| PMR35MF | 35 psi | 115 psi | 2 - 20 gpm | 3/4" F NPT, 1" F NPT, 1" F BSPT | 3/4" F NPT, 1" F NPT, 1" F BSPT |
| PMR40MF | 40 psi | 120 psi | 2 - 20 gpm | 3/4" F NPT, 1" F NPT, 1" F BSPT | 3/4" F NPT, 1" F NPT, 1" F BSPT |
| PMR50MF | 50 psi | 130 psi | 2 - 20 gpm | 3/4" F NPT, 1" F NPT, 1" F BSPT | 3/4" F NPT, 1" F NPT, 1" F BSPT |
| PMR60MF | 60 psi | 140 psi | 2 - 20 gpm | 3/4" F NPT, 1" F NPT, 1" F BSPT | 3/4" F NPT, 1" F NPT, 1" F BSPT |
The pressure regulator shall maintain the predetermined operating pressure provided that the inlet pressure is at least 5 psi above the expected outlet pressure, but not exceeding the maximum inlet pressure as shown above.
Recommended for outdoor use only. Not NSF certified.
PR-HF
| PR-HF MODELS | Preset Outlet Pressure | Maximum Inlet Pressure | Flow Range | Inlet Sizes | Outlet Sizes |
| PR10HF | 10 psi | 90 psi | 10 - 32 gpm | 1¼" F NPT, 1¼" F BSPT | 1" F NPT, 1¼" F NPT, 1" F BSPT, 1¼" F BSPT |
| PR15HF | 15 psi | 95 psi | 10 - 32 gpm | 1¼" F NPT, 1¼" F BSPT | 1" F NPT, 1¼" F NPT, 1" F BSPT, 1¼" F BSPT |
| PR20HF | 20 psi | 100 psi | 10 - 32 gpm | 1¼" F NPT, 1¼" F BSPT | 1" F NPT, 1¼" F NPT, 1" F BSPT, 1¼" F BSPT |
| PR25HF | 25 psi | 105 psi | 10 - 32 gpm | 1¼" F NPT, 1¼" F BSPT | 1" F NPT, 1¼" F NPT, 1" F BSPT, 1¼" F BSPT |
| PR30HF | 30 psi | 110 psi | 10 - 32 gpm | 1¼" F NPT, 1¼" F BSPT | 1" F NPT, 1¼" F NPT, 1" F BSPT, 1¼" F BSPT |
| PR40HF | 40 psi | 120 psi | 10 - 32 gpm | 1¼" F NPT, 1¼" F BSPT | 1" F NPT, 1¼" F NPT, 1" F BSPT, 1¼" F BSPT |
| PR50HF | 50 psi | 130 psi | 10 - 32 gpm | 1¼" F NPT, 1¼" F BSPT | 1" F NPT, 1¼" F NPT, 1" F BSPT, 1¼" F BSPT |
The pressure regulator shall maintain the predetermined operating pressure provided that the inlet pressure is at least 5 psi above the expected outlet pressure, but not exceeding the maximum inlet pressure as shown above.
Recommended for outdoor use only. Not NSF certified.
PRU
| PRU MODELS | Preset Outlet Pressure | Maximum Inlet Pressure | Flow Range | Inlet Sizes | Outlet Sizes |
| PRU10 | 10 psi | 90 psi | 20 - 100 gpm | 2" F NPT, 2" F BSPT | 2" F NPT, 2" F BSPT |
| PRU15 | 15 psi | 95 psi | 20 - 100 gpm | 2" F NPT, 2" F BSPT | 2" F NPT, 2" F BSPT |
| PRU20 | 20 psi | 100 psi | 20 - 100 gpm | 2" F NPT, 2" F BSPT | 2" F NPT, 2" F BSPT |
| PRU25 | 25 psi | 105 psi | 20 - 100 gpm | 2" F NPT, 2" F BSPT | 2" F NPT, 2" F BSPT |
| PRU30 | 30 psi | 110 psi | 20 - 100 gpm | 2" F NPT, 2" F BSPT | 2" F NPT, 2" F BSPT |
| PRU40 | 40 psi | 120 psi | 20 - 100 gpm | 2" F NPT, 2" F BSPT | 2" F NPT, 2" F BSPT |
| PRU50 | 50 psi | 130 psi | 20 - 100 gpm | 2" F NPT, 2" F BSPT | 2" F NPT, 2" F BSPT |
| PRU60 | 60 psi | 140 psi | 20 - 100 gpm | 2" F NPT, 2" F BSPT | 2" F NPT, 2" F BSPT |
The pressure regulator shall maintain the predetermined operating pressure provided that the inlet pressure is at least 5 psi above the expected outlet pressure, but not exceeding the maximum inlet pressure as shown above.
Recommended for outdoor use only. Not NSF certified.
PRU-LV
| PRU-LV MODELS | Preset Outlet Pressure | Maximum Inlet Pressure | Maximum Flow | Inlet Sizes | Outlet Sizes |
| PRU LV 10 | 10 psi | 125 psi | up to 100 gpm | 2" F NPT, 2" F BSPT | 2" F NPT, 2" F BSPT |
| PRU LV 15 | 15 psi | 125 psi | up to 100 gpm | 2" F NPT, 2" F BSPT | 2" F NPT, 2" F BSPT |
| PRU LV 20 | 20 psi | 125 psi | up to 100 gpm | 2" F NPT, 2" F BSPT | 2" F NPT, 2" F BSPT |
| PRU LV 25 | 25 psi | 125 psi | up to 100 gpm | 2" F NPT, 2" F BSPT | 2" F NPT, 2" F BSPT |
| PRU LV 30 | 30 psi | 125 psi | up to 100 gpm | 2" F NPT, 2" F BSPT | 2" F NPT, 2" F BSPT |
| PRU LV 40 | 40 psi | 125 psi | up to 100 gpm | 2" F NPT, 2" F BSPT | 2" F NPT, 2" F BSPT |
| PRU LV 50 | 50 psi | 125 psi | up to 100 gpm | 2" F NPT, 2" F BSPT | 2" F NPT, 2" F BSPT |
| PRU LV 60 | 60 psi | 125 psi | up to 100 gpm | 2" F NPT, 2" F BSPT | 2" F NPT, 2" F BSPT |
The PRU-LV limits downstream pressure to no more than 15 psi above regulated pressure during static (no flow) conditions.
Recommended for outdoor use only. Not NSF certified.
PRLV
| PRLV MODELS | Preset Outlet Pressure | Maximum Inlet Pressure | Maximum Flow | Inlet Sizes | Outlet Sizes |
| PRLV10 | 10 psi | 125 psi | 18 gpm | 3/4" F NPT, 1" F NPT | 3/4" F NPT, 1" F NPT |
| PRLV15 | 15 psi | 125 psi | 18 gpm | 3/4" F NPT, 1" F NPT | 3/4" F NPT, 1" F NPT |
| PRLV20 | 20 psi | 125 psi | 18 gpm | 3/4" F NPT, 1" F NPT | 3/4" F NPT, 1" F NPT |
| PRLV30 | 30 psi | 125 psi | 18 gpm | 3/4" F NPT, 1" F NPT | 3/4" F NPT, 1" F NPT |
| PRLV40 | 40 psi | 125 psi | 18 gpm | 3/4" F NPT, 1" F NPT | 3/4" F NPT, 1" F NPT |
| PRLV50 | 50 psi | 125 psi | 18 gpm | 3/4" F NPT, 1" F NPT | 3/4" F NPT, 1" F NPT |
| PRLV60 | 60 psi | 125 psi | 18 gpm | 3/4" F NPT, 1" F NPT | 3/4" F NPT, 1" F NPT |
The pressure regulator shall maintain the predetermined operating pressure provided that the inlet pressure is at least 5 psi above the expected outlet pressure, but not exceeding the maximum inlet pressure as shown above.
Recommended for outdoor use only. Not NSF certified.