Welcome Page Body
Section Menu
Installation
-
Controller Installation
The AC2 installation guide will have the following information:Removing Front Door and Face FrameWall MountingWiring Controller PowerWiring DiagramConduit SizesComponents of the
-
Flow Sensor Installation
Flow Sensors allow flow-capable controllers, such as the Hunter ACC2, to monitor actual flow in irrigation systems. With proper setup at the controller, this allows the controller
-
Centralus Installation
The A2C controller uses three different types of communication devices: a WiFi module, a Local Area Network (LAN), or the LTEM cellular connection. For more information on
-
Decoder Staking kit
The DECODER STAKE raises the decoder off the ground to provide easy access for wireless programming tools (ICD-HP & EZ-DT) during routine maintenance, keep wiring and connections
Controller Connections and Tips
-
Facepack
"Facepack" is a Hunter term for the enclosed, removable control panel and display assembly. It contains the brain and memory of the controller.
-
Components (Decoder)
External Components1 Front Door2 Face Frame3 Facepack4 Face Frame Latch5 Facepack CableThe facepack cable connection is located beneath the Status Light. It is a standard
-
Communication Module Ribbon Update
The communication module connection to the ACC2 facepack changed, effective with a facepack manufacturing date code May 2022 and later. The new facepack now has a separate
-
SmartPort® Replacement
The SmartPort® wiring harness is included with the ACC2 model controllers. This harness is designed to activate stations on-site using the ROAM, ROAMXL, and ROAMLR Hunter remotes.
-
WiFi Direct Connect
The controller can be placed in direct connect mode, allowing an iOS or Android device to connect directly over Wi-Fi to a single controller. This removes the need to go through
Decoder Connection and Tips
-
ID Wire
Wire and wire installation are key factors in successful decoder installations. Substitution of recommended wire and wire splices is at the installer’s own risk and is a major
-
Diagnostic LED Lights
Each decoder output module is equipped with diagnostic LED lights. Each light is labeled on the deck lid.
-
ICD Decoder Installation
Proper installation and connection of the decoder's two-wire paths is very important. Learn moreUse only Hunter IDWIRE or an approved substitute.Use only Hunter DBRY-6 waterproof
Home and Activity Screens
-
Home and Activity Screens
The Home screen displays key system information and provides soft-key shortcuts to commonly used functions. The current date and time are shown along the bottom-left border.
-
Manual Starts and Test
From the Home screen, the MANUAL soft key allows you to start stations/blocks, programs, and run a test program. A Manual Station or Program Start will pause any automatic watering
-
Stop Commands
Any running irrigation can be stopped immediately from the Home screen. The top soft key offers the following choices for stopping irrigation: Stop All Irrigation - Stops
-
Attention Messages
A new controller installation will begin with at least one or two Attention messages, because the controller has experienced a "power outage" in shipping, and may be discovering
Programs Menu
-
Program Start Times
A basic program requires a START TIME, station Run Time, and Water Days to operate automatically. This is where basic automatic irrigation is set up. There are 32 possible
-
Program Run Times
The ACC2 Controller can have a maximum of 64 RUN TYPES (events) for each program that may consist of a station, a block (a group of stations), and/or a station delay. Station
-
Program Water Days
Setting the WATER DAYS will complete a basic automatic program. Mode Options: Day of Week: Check the boxes for the days the program should water. Odd/Even: Water only
-
Program Seasonal Adjust
SEASONAL ADJUSTMENT is used to make run time changes without having to reprogram all of the individual station run times. This feature is perfect for making small changes that are
-
Program Calendar Days Off
Create a list of dates on which the controller (all programs) will not be allowed to run, regardless of Water Day settings. Programs that have been set to Ignore Calendar Days Off
-
Program Summary
Once a program has start times, run times, and water days, it will run automatically without further setup. To see how the program is configured, select Program Summary from the
-
Program Rules
PROGRAM RULES customizes each program for setting up a NO WATER WINDOW or STATION DELAY. Ignore Calendar Days Off: Check the box if the program should be allowed to
Stations Menu
-
Station Setup
The primary use for this setting is to allow stations to be named. Most other functions are described in more detail in the Flow Operations section. Name: Used to name the
-
Cycle & Soak
Used to control runoff and puddles when the soil or slope cannot absorb all the irrigation at once.Set the Cycle to the maximum time the station can run at once, before runoff
-
Blocks
A BLOCK is an electronic group of stations that runs at the same time, for the same run time, within a program (Blocks replace “SSGs” in original ACC).Blocks may have up to 8
-
Station Limits
STATION LIMITS will allow you to set how many stations can run at once. Stack or Overlap means that each program can be manually set to overlap with other programs or be
-
Station Summary
The STATION SUMMARY is a report available for each station showing exactly how it is going to run, based on the current setup and programming. It is a report only and does not
Devices Menu
-
P/MV Operation
The ACC2 controller allows up to six Pump and/or Master Valve outputs to be assigned in the controller. This applies to the decoder and conventional models.
-
Flow Sensors
After connecting one or more flow sensors to the controller, the next step is to configure the sensor in the FLOW SENSORS menu. The controller has three Flow Sensor inputs built-in
-
Solar Sync
After connecting a SOLAR SYNC Sensor to the controller, it is necessary to configure this in the Devices, SOLAR SYNC menu. It will take the SOLAR SYNC two or three days to register
-
Clik Sensors
The ACC2 Controller allows you to connect up to three CLIK SENSORS. These sensor inputs are already configured as Normally Closed, but this can be changed for other types of
-
Sensor Response
The SENSOR RESPONSE is set up by the individual program. If you want the same responses for multiple programs, set up the responses for the first program, then click the Copy soft
-
Sensors (Decoder)
Rain shutoff and other sensors must be setup in the Devices menu. We tell the controller what sensors are connected, and in some cases we set the response for each sensor. Clik
-
Sensors
Rain shutoff and other sensors must be setup in the Devices menu. Clik SensorsDial to the Devices menu, and select Clik Sensors for basic Hunter "Clik" sensors. To set up a sensor,
Flow Menu
-
Flow Operations
The two major components of FLOW OPERATIONS are the Flow Manager and the Flow Monitor features. Checking either will display a reminder of the steps required to set up these
-
Flow Totals
FLOW TOTALS are total amounts of water consumed over a specified time period. They may also be viewed at different levels, depending on how the controller is configured. Total Flow
-
Mainsafe
A MAINSAFE is an optional level of flow monitoring and protection above the Flow Zone level. This is a useful feature when the following occurs: More than one Flow Zone has
-
Learn Flow
LEARNING FLOW is an important step in the Flow Monitor setup (unless the MainSafe™ option is enabled) process. Flow learning will only test stations that already have a Run
-
Clear Flow Alarms
The CLEAR FLOW ALARM function enables a MainSafe or Flow Zone that has had an Overflow alarm to water again. If a Flow Zone or MainSafe flow alarm has occurred, a shortcut key is
-
Hydraulic Summary
The HYDRAULIC SUMMARY is a report of exactly how the controller hydraulics are set up at the moment. It shows the connections of all flow-related objects, from MainSafe zones (if
-
Flow Alarm Handling
When stations are running, the Flow Monitor continuously checks the actual flow from the sensor(s) against the combined learned flow of the stations, including the overflow and
Settings Menu
-
Regional Settings
The REGIONAL SETTINGS menu allows you to change the LANGUAGE, TIME AND DATE format, and UNIT OF MEASUREMENTS in your ACC2 controller.
-
Networking
The ACC2 model controller can be upgraded to Centralus software for web-based central control options. Installing the A2C-WIFI (WiFi Module), A2C-LAN (Ethernet networking module),
-
Controller Verification
When the ACC2 model controller is upgraded to web-based central control Centralus Software, a VERIFICATION CODE is required to complete the installation process. After a valid
Diagnostics Menu
-
View Logs
Attention messages do not interfere with normal automatic irrigation. All attention messages on the Home screen create logs. The first step to understanding any problem or message
-
Module Info
Select Module Info to see the current version of all firmware in all modules and components. Module slots or components that are empty or not reporting are shown as Not Present
-
Clik Sensor Diagnostics
Sensor: Shows each sensor and name.State: Shows the current status of the sensor."Inactive" means the sensor is normal."Active" means the sensor is currently alarmed."Delayed"
-
Station-P/MV Diagnostics
Shows the electrical current draw in milliamps for all active stations and P/MV outputs.
-
Flow Sensor Diagnostics
Shows the configuration of each flow sensor and current flow. Frequency shows the click or pulse rate from the sensor, for diagnostic purposes.
-
Solar Sync Diagnostics
Shows the last time the Solar Sync sensor communicated, and the current state of its alarm sensors (Rain and Freeze). This soft key is only shown if Solar Sync has been set up in
-
Decoder Wire Test Mode
The WIRE TEST Feature will activate a 24 VAC-60 Hz frequency on all output modules and their two-wire paths, to allow wire tracking and fault finding with a standard AC current
Advanced Features
-
Export Logs
Logs may be exported to the internal SD card in the facepack in a simple text format if additional help is needed for troubleshooting or just for record-keeping.
-
Easy Retrieve
East Retrieve saves the current controller setup so it can be restored to this point in the future. This is especially helpful after a complicated flow operations setup, since all
-
Reset Memory
The ACC2 controller can be RESET, erasing most programmed information. There are 2 different levels of the Reset command's available. If any of them are chosen, the information
-
Firmware Updates
The ACC2 Controller can be updated whenever a new version of the operating system or any internal module becomes available. To ensure optimal performance and security, it is
Conditional Response
-
About Conditional Response
Conditional Responses allow a sensor or condition to trigger something to happen. This can be as simple as telling a station to start when a sensor is opened, to much more complex
-
SOS
Status Output Station An SOS is a dedicated station output that is only used with Conditional Response. The purpose of the SOS is to trigger an external light or other device
-
SOS (Decoder)
SOS (Status Output Station) An SOS is a dedicated station output that is only used with Conditional Response. The purpose of the SOS is to trigger an external light or other
-
Switch P/MVs
To enable P/MV switching on sensor input, each station in the affected Flow Zone should be set to call for both P/MV outputs. When the sensor is alarmed or changes position, it
-
Conditional Response Setup
Dial to Advanced Settings and select Conditional Response. Each response has a soft key for the “If” condition, a “Then” condition or action, and “Review Statement” to verify that
-
Start Stations, Programs, and Blocks
When using Conditional Response to start a station, Block, or program, other options appear below the selection. Mode If the Mode is set to Manual, the station,
Decoders Menu
-
About Decoders Menu
ACC2 Decoder controllers have an additional menu for decoder functions. ACC2 is designed to work with Hunter ICD decoders, and will not operate decoders from other manufacturers.
-
View Configuration
View Configuration can retrieve all the setup information for a specified decoder on the two-wire path, or for one attached to the programming port. It is similar to the Read
-
Station Assignments
When multiple decoder output modules are present, the range of station numbers allowed on each one can be changed, or "mapped." This allows you to assign more than 75 stations to a
-
Decoder Diagnostics
The Diagnostics screen displays an overview of the electrical status of each installed output module, plus additional functions.Each module’s electrical current is shown. When no
-
Decoder Inventory
This runs a test communication to all decoder addresses on the selected output module to verify which decoders are installed and operational on the two-wire paths. Use the
-
Update ICD Decoders
You can update any installed decoder on the two-wire path using the ICD-HP tool. The current ICD-HP programmer firmware version is 1.15 and can be downloaded into your tool from
-
Program Decoder
This allows setting or changing a decoder’s station address(es). Hunter decoders must have at least one station number programmed into the decoders before they will operate. In
Troubleshooting
-
Troubleshooting Chart
Symptom Solution Attention Messages Press View Messages, and/or View Logs Continue troubleshooting
-
No Network Card Message
The NO NETWORK CARD PRESENT message could appear on your Network Info screen if the module was removed, then reinstalled. Also, a zero could display for the IP number. Use the
-
Advanced Electrical Troubleshooting
This video provides an overview of two-wire irrigation systems and effective troubleshooting techniques. It covers system fundamentals, including wire path planning, grounding,
FAQ's
-
Decoders
ACC2 Decoder is designed to operate Hunter ICD decoders. The ICD decoders must be programmed with station numbers before they will operate. See the DECODER MENU for detailed
-
P/MV Manual Run
From the Home screen, the Manual soft key allows you to start stations/blocks, programs, and run a test program. Any manual start will pause any automatic watering until the cycle
-
Station P/MV Usage Marked X
The ACC2 Controller can allocate the P/MV terminals to a Flow Zone. When this setting is enabled, the Station P/MV Usage box will be marked with an "X." This can easily be disabled