The MCC controller is supplied with one factory-installed power module and one station module for eight stations. Additional station modules may be added in eight-station increments to expand the controller’s station capacity. All model MCC Controllers can be expanded to 108 stations.
IMPORTANT: Only the following output modules are compatible with the MCC: ICM-800 and ICM-2200 Output Modules; EZ-DM Decoder Output Modules that say “Enhanced” or “MCC Compatible” on the box; all Wireless Valve Output Modules. ICM-400 Output Modules are not compatible with the MCC. All enhanced modules are still backward-compatible with the ICC2.
| Module | Description | Compatibility Notes |
|---|---|---|
| ICM-400 | 4 station output module | NOT compatible with MCC |
| ICM-800 | 8 station output module | Compatible date code MAR 26 or later. Air vents in cover of new ones. |
| ICM-2200 | 22 station output module | Compatible date code MAR 26 or later. Air vents in cover of new ones. |
| EZ-DM | 54 station EZ Decoder module | Compatible date code MAR 26 or later. Older modules will not fit into MCC slots. A second EZDM can be installed to allow up to 108 stations. |
| WVOM | 108 station Wireless Valve Link | All Models |
| A2CLTEM | Cellular communication module | All Models |
| A2CWIFI | WiFi communication module | All Models |
| A2CLAN | Ethernet communication module | All Models |
Station Module
- Insert the module tabs into the slot and tip into place. (ICM-2200 will only work in slots 5 and 6.)
- Close the locking lever.
- Press the RESET button on the back of the facepack after any module changes.
- Verify the new station count in the run times dial position.
Still need help? We're here.
Tell us what you need support with and we'll find the best solution for you.